Programming IDEC SmartRelay
Note
Press
to the end of the Co list: lo, hi, ..... to I1.
Inputs F1, F2, F3, and F4 are new as of the FL1E device series.
They correspond to the four function keys on the optional Text Dis-
play.
I1
Press OK. I1 is now connected to the input of the OR block.
The cursor jumps to the next input of the OR block.
The display now shows:
I1
Now you connect input I2 to the input of the OR block. You
already know how to do this:
1. Switch to editing mode:
2. Select the Co list:
3. Confirm the Co list with:
4. Select I2:
5. Apply I2:
I2 is now connected to the input of the OR block:
The display now shows:
I1
I2
74
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
to go the start of the Co list: I1, I2 .... to lo. Press
B1
1
Q1
B1
1
Q1
B1
1
Q1
Your complete circuit program
in IDEC SmartRelay up to now:
B1
1
I1
Press OK
Press
or
Press OK
Press
or
Press OK
Your circuit program layout in
IDEC SmartRelay up to now
B1
1
I1
I2
IDEC SmartRelay Manual
to go
Q1
Q1

Hide quick links: