IDEC FL1E-H12RCA User Manual page 197

Fl1e series. smartrelay
Table of Contents

Advertisement

Analog comparator (actual value Ax - Ay, see Chapter
4.4.18)
Analog trigger (actual value Ax, see Chapter 4.4.16)
Analog amplifier (actual value Ax, see Chapter 4.4.20)
Analog multiplexer (actual value AQ, see Chapter 4.4.26)
Analog ramp control (actual value AQ, see Chapter
4.4.27)
Analog math (actual value AQ, see Chapter 4.4.30)
PI controller (actual value AQ, see Chapter 4.4.28)
Up/down counter (actual value Cnt, see Chapter 4.4.13)
Select the required function by the block number.
Parameter p (number of decimals)
Applies only to the Aen, Ax, 
message text.
Timing diagram
Functional description
A 0 to 1 transition at input En saves the value of the signal at
the analog input Ax. This saved process variable is referred
to as "Aen".
Both the analog actual values Ax and Aen are multiplied by
the value at parameter A (gain), and parameter B (offset) is
then added to the product: 
(Ax•gain) + offset = Actual value Aen, when input En
changes from 0 to 1, or
(Ax•gain) + offset = Actual value Ax.
Output Q is set when the signal at input En = 1 and if the
actual value at input Ax is out of range of
Output Q is reset, when the actual value at input Ax lies
within the range of
input En changes to lo.
IDEC SmartRelay Manual
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
En
Aen +
1
Aen
Aen –
2
Ax
Q
Aen -
IDEC SmartRelay functions
and 
values displayed in a
1
2
Aen -
, or when the signal at
2 to Aen+
1
.
2 to Aen +
1
183