IDEC SmartRelay functions
Example 6: Yearly mode off, Monthly mode off, Pulse
selected, On Time = 2008
March 15, 2008 the timer output switches on for one cycle.
Because the timer does not have a monthly action or yearly
action, the timer output pulses only one time at the specified
On Time.
B6
Yearly =Off
Monthly=Off
Pulse
Example 7: Yearly mode on, Monthly mode off, Pulse off,
On Time = 2008
December 15 of 2008 and 2009, the timer output switches on
and remains on until January 7 of the following year. When
the timer output turns off on January 7, 2010 it does NOT
turn on again the following December 15.
B6
Yearly = On
Monthly=Off
Pulse
158
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
03
1+
B6
ON :
YYYY–MM–DD
=On
2008–03–15
12
15, Off Time = 2010
1+
B6
ON :
YYYY–MM–DD
=Off
2008–12–15
15, Off Time = ****
B6
2+
OFF :
YYYY–MM–DD
****–**–**
01
07: On
B6
2+
OFF :
YYYY–MM–DD
2010–01–07
IDEC SmartRelay Manual
**
**: On
3+
3+