Circuit program
S1 is connected to the I1 and S2 to the I2 input connector of
the OR block.
The corresponding layout of the circuit program in IDEC
SmartRelay:
I1
I2
x
Wiring
The corresponding wiring:
S1 switches input I1, while S2 switches input I2. The load is
connected to the relay Q1.
IDEC SmartRelay Manual
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
1
L1
N
L1
1
Q1
L
N
Programming IDEC SmartRelay
Q1
S1
S2
N
I1 I1
I1 I1
I3
I4
I5
I2
2
1
2
1
2
Q2
Q3
I6
I7
I8
1
2
Q4