The result of the multiplication (long) is not limited.
As long as status TRUE is present at I4 (Master Reset), the output value is 0.
The output value at O2 is not the inverted value of O1.
The output can be combined with inputs for position values (Long).
Note:
Percentages [%] have two decimals.
For example: Value 12345
5.3.3

Division

5.3.3.1
Type
%
Input (numerator)
I1
Input (denominator
I2
%
1)
Input (denominator
I3
%
2)
I4
b
Master Reset
Description:
The input value at I1 is divided by the product from input values I2 and I3.
I1
O1
O
2
=
=
I2
×
The result of the division is limited to -P2 and +P1 (max. to ±327.67%).
P2 is the negative limit (-P2), even if only a positive value can be entered for P2.
As long as status TRUE is present at I4 (Master Reset), the output value O1 is 0.
Signal source "9 - Zero" or the value 0 at input I2 or I3 deactivates these inputs. In this case,
no division by the input values at I2 and I3 is carried out. The input values are processed as
I2=1 and I3=1.
Example:
I1=14000 (=140.00%)
I2=3000 (=30.00%)
I3=3233 (=32.33%)
Note:
Percentages [%] have two decimals.
For example: Value 12345
If EI2 or I3 has value 0, output O1 has value I1.
94
94
= 123.45% = 1.2345
IN
[336] Division
Function
O1
O2
P1
P2
I3
O1
= 140.00% / 130.00% / 32.33%
= (1.4000 / 0.3000 / 0.3233)
= |14434.47%| limit
= 327.67%
= 123.45% = 1.2345
IN
Type
Function
I1
%
O1
=
I2
×
I3
%
inverted output = -1
%
upper limit
%
lower limit
VPLC / PLC
VPLC / PLC
08/10
08/10