BONFIGLIOLI AGILE Applications Manual page 31

Hide thumbs Also See for AGILE:
Table of Contents

Advertisement

Delay Superior
52 -
min (non-
retriggerable)
Timer functions
Monoflop Supe-
60 -
rior ms (retrig-
gerable)
Monoflop Supe-
61 -
rior s (retrigger-
able)
Monoflop Supe-
62 -
rior min (retrig-
gerable)
Monoflop Supe-
70 -
rior ms (non-
retriggerable)
Monoflop Supe-
71 -
rior s (non-
retriggerable)
Monoflop Supe-
72 -
rior min (non-
retriggerable)
Clock generator
80 -
Superior ms
Clock generator
81 -
Superior s
Clock generator
82 -
Superior min
Digital switches
Digital Multi-
90 -
plexer
Dataset chan-
91 -
geover
Error functions
Triggering of an
95 -
error.
Acknowledging
96 -
an error.
Zero operation
99 - NOP
08/10
08/10
As in operation mode 50, the unit of the times set in P1 and P2 is
minutes [min]. See chapter 4.5.3.
Output signal becomes TRUE with positive clock edge at input 1 or
with negative clock edge at input 2. The time set in P1 is the On-
Time (High) and the time set in P2 is the ignore edge time (Low).
The time is indicated in milliseconds [ms]. The set on-time and the
ignore edge time start again with each edge.
TRUE at Superior-Set input (input 3) sets output TRUE. TRUE at
Superior Reset input (input 4) sets output FALSE. See chapter 4.6.1.
As in operation mode 60, the unit of the times set in P1 and P2 is
seconds [s]. See chapter 4.6.1.
As in operation mode 60, the unit of the times set in P1 and P2 is
minutes [min]. See chapter 4.6.1.
Output signal becomes TRUE with positive clock edge at input 1 or
with negative clock edge at input 2. The time set in P1 is the On-
Time (High) and the time set in P2 is the ignore edge time (Low).
The time is indicated in milliseconds [ms]. Edges during the selected
ON time and the ignore edge time will be ignored.
TRUE at Superior-Set input (input 3) sets output TRUE. TRUE at
Superior Reset input (input 4) sets output FALSE. See chapter 4.6.3.
As in operation mode 70, the unit of the times set in P1 and P2 is
seconds [s]. See chapter 4.6.3.
As in operation mode 70, the unit of the times set in P1 and P2 is
minutes [min]. See chapter 4.6.3.
As long as input 1 is TRUE and input 2 is FALSE, the set pulse pat-
tern is output. The clock pattern is defined by the on-time and the
off-time. The time set in P1 is the on-time (High) and the time set in
P2 is the off-time (Low). The time is indicated in milliseconds [ms].
TRUE at Superior-Set input (input 3) sets output TRUE. TRUE at
Superior Reset input (input 4) sets output FALSE. See chapter 4.6.5.
As in operation mode 80, the unit of the times set in P1 and P2 is
seconds [s]. See chapter 4.6.5.
As in operation mode 80, the unit of the times set in P1 and P2 is
minutes [min]. See chapter 4.6.5.
Depending on the current data set, the input values are forwarded to
the output values
Data set = 1: Output 1 = Input 1,
Data set = 2: Output 1 = Input 2,
Data set = 3: Output 1 = Input 3,
Data set = 4: Output 1 = Input 4
See chapter 4.7.1.
Switching-over of data set depending on input signals. See chapter
4.8.1.
A user error is triggered via one of the inputs I1 ... I4. The behavior
(error cut-off, shut-down, emergency stop) after triggering can be
set up via P2. See chapter 4.9.1.
Output 1 indicates if an acknowledgeable error message is present.
Via inputs I1 or I2, the error message can be acknowledged. See
chapter 4.9.2.
Zero operation. The function does not carry out an operation. See
chapter 4.11.1.
VPLC / PLC
VPLC / PLC
Digital functions
Digital functions
Digital functions
Digital functions
29
29

Hide quick links: