Writing of the EEPROM is restricted to approx. 1 million times. If this number is
exceeded, the device may be damaged.
Definition:
Input buffer RAM = input buffer EEPROM +5
Write index and read index for the "Input buffer analog" table
VPlus
Parameter
FT-write index (FT-input analog)
FT-read index (FT-input analog)
FT-input buffer frequency
FT-input buffer current
.
.
.
6.2

Run/Stop

By default (factory setting) the function table is stopped and must be started by parameter
RunMode
1399 . In stop mode, no instructions are processed and there is no writing of the
output buffer.
Note:
Instructions can only be edited in stop mode. If you try to make any changes while the func-
tion table is not in stop mode, an error will be displayed in VPlus. The attempted change will
not be applied.
Further operation modes are available for processing individual instructions and instruction
blocks. If an operation mode 11, 12, 21, 22, 31 or 32 is selected, the instruction block
processed according to the function described.
matically. In order to process another instruction block, the operation mode must be set to the
corresponding value again.
FT-Runmode
0 - Stop
1 - Run
2 - Continue
11 -
Single Step
12 -
21 -
Single Part
22 -
31 -
Single Cycle
32 -
Note:
Two modes are available to an instruction block (1x, 2x, 3x).
1
In this connection, an instruction block may also include a single instruction.
08/10
08/10
Data set 0
2
1377
2
1378
62 - Reference Frequency Channel
1379
1380
126 - Active Current
...
...
VTable
Input buffer analog
FT-input buffer frequency
FT-input buffer current
.
.
.
1399
The function table is stopped and no longer processed.
The function table is started at index 1 and processed normally.
The function table is continued at the index where the processing was
stopped last time, and the table is then processed normally.
One instruction is processed.
All instructions are processed until next writing of output buffer.
All instructions are processed until return jump. The return jump is
reached when the maximum number of logic functions is processed or
FT-Instruction
the next
Index 1
9 - Zero
1379
9 - Zero
1380
...
...
...
Then, Run mode will be set to "0-Stop" auto-
Function
1343 = 0.
VPLC / PLC
VPLC / PLC
Index 2
62 - Reference Frequency Channel
126 - Active Current
...
...
...
FT-
1
will be
137
137

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Active cube

Table of Contents