[383] Spike filter (average of three)

Type
%
Input value
I1
%
Start value
I2
I3
b
Master Set
b
Master Reset
I4
Description:
The input value at I1 is filtered.
The average of the current input value and the two previous input values is output. In this way
individual input spikes are suppressed.
− Master Set: TRUE sets the output to the start value. The start value can be defined via input
I2.
− Master-Reset: TRUE sets the output to 0.
− Master Reset has priority over Master Set.