5.7.2

Reading parameters

Read access enables direct reading of all parameters of the frequency inverter. This is useful if
the parameter is not connected to a source. Since the read access is effected to the non-
realtime system of the frequency inverter, an instruction may take longer than 1 ms. The in-
struction is processed for the duration of the parameter access even if this takes longer than 1
ms.
If a non-permissible data set or index is selected, it will be replaced by one of the following
data sets or indices.
Data Set/
Index
0
1...4/
1...max. index
Invalid value
All data sets are accessed from the RAM. Internal access to the EEPROM and RAM is done in
the same way.
5.7.2.1
Type
-
-
I1
-
-
I2
I3
b
Release read access
-
-
I4
Description:
The function reads the value of the parameter set up in P1 "Parameter number" and P2 "Data
set/index". The value is converted to a frequency value. Via Input I3 read access is enabled.
I3 = 0:
No read access.
I3 = 1:
The parameter value is read. The instruction is executed until the value is read.
5.7.2.2
Type
-
-
I1
I2
-
-
b
Release read access
I3
-
-
I4
Description:
The function reads the value of the parameter set up in P1 "Parameter number" and P2 "Data
set/index". The value is converted to a current value. Via Input I3 read access is enabled.
I3 = 0:
No read access.
I3 = 1:
The parameter value is read. The instruction is executed until the value is read.
116
116
Data set related parameters
Instead, data set 1 is used.
Instead, index 1 is used.
Value of data set 1...4
Value from index 1...max. Index
Instead, data set 1 (or index 1) is used.

[421] Read frequency parameter

Function

[422] Read current parameter

Function
Non-data set related pa-
rameters
Data set 0
Data set 0
Data set 0
Type
Function
%
Parameter value [Hz]
O1
%
inverted output = -1
O2
P1
i
Parameter number
i
Data set (0 ... 4)/index
P2
Type
Function
%
Parameter value [A]
O1
O2
%
inverted output = -1
i
Parameter number
P1
i
Data set (0 ... 4)/index
P2
VPLC / PLC
VPLC / PLC
08/10
08/10