Description:
The function sets output O1 to TRUE if a motion block is running.
If input I4 (wait) is set, further instructions will only be processed when the motion block (in-
cluding repetitions, if applicable) or automatic sequence of motion blocks is finished. The
process cannot be stopped by other instructions or resetting I3.
Motion block
running
yes
no
yes
5.11

Bit functions for analog input values

Each individual bit of input 1 is combined with the corresponding bits of input 2 and parame-
ter 1 (if available to the selected function). The result is saved in the corresponding bit of the
output value.
For example, bit 3 of the output value depends on
− bit 3 of input value 1 and
− bit 3 of input value 2 and
− Bit 3 of parameter 1.
Parameter 2 indicates of input value I1 is to be combined with input value I2 or parameter P1:
− P2 = 1: Combination of input value I1 with input value I2
− P2 = 2: Combination of input value I1 with parameter P1
− P2 = 3: Combination of input value I1 with input value I2 and parameter P1
Master Set sets all bits of the output value (Output = 0xFFFF).
Master Reset deletes all bits of the output value (Output = 0x0000).
At output O2, the bitwise inverted value O1 is output.
Example: O1 = 0xFF00

5.11.1 [200] Bit NOT operation

Type
%
input value 1
I1
I2
-
-
b
Master Set
I3
I4
b
Master Reset
Description:
At output 1 O1, the bitwise inverted value of input I1 is output (O1 = 1 I ).
126
126
I4
O1=
0
1
x
0
1
Wait
O2 = 0x00FF.
Function
Type
%
O1
O2
%
-
P1
P2
-
VPLC / PLC
VPLC / PLC
Function
1 I (I1 bitwise inverted)
inverted output (=I1)
-
-