7.5
Signal sources for device function
Signal sources of the instructions can be assigned to the device functions for further processing.
The values are updated when the output buffer is written.
Digital
2401 ... 2416 - PLC output buffer 1 ... 16
Analog
2501 ... 2504 - PLC outp. frequency 1 ... 4
2511 ... 2514 - PLC outp. current 1 ... 4
2521 ... 2524 - PLC outp. percent 1 ... 4
2531 ... 2534 - PLC outp. voltage 1 ... 4
2551 ... 2554 - PLC outp. user 1 ... 4
2561 ... 2564 - PLC flag 1 ... 4
7.6
Error messages of instruction "95 - Triggering an error"
Error
User error 1. In instruction "95 - Triggering of an error" shut-down behavior P1
F3031
was triggered via input I1.
User error 2. In instruction "95 - Triggering of an error" shut-down behavior P1
F3032
was triggered via input I2.
User error 3. In instruction "95 - Triggering of an error" shut-down behavior P1
F3033
was triggered via input I3.
User error 4. In instruction "95 - Triggering of an error" shut-down behavior P1
F3034
was triggered via input I4.
08/10
08/10
Signal source
VPLC / PLC
VPLC / PLC
Description
147
147