4.2.1
Chronological behavior
The setup of P1 and P2 affects the following instructions:
40 ... 42 / 140 ... 142
50 ... 52 / 150 ... 152
60 ... 62 / 160 ... 162
70 ... 72 / 170 ... 172
80 ... 82 / 180 ... 182
The units of P1 and P2 may be set to milliseconds [ms], seconds [s] or minutes [min]. The unit
of the entered value depends on the instruction.
Note:
Time set for P1 and P2,
− are limited internally to the maximum value of 24 days
− are not continued when the frequency is switched off and on again. The sequence is res-
tarted from the beginning after re-activation.
4.2.2
Jump target
The evaluation of P1 and P2 affects the following instruction:
100
Description
P1
P2
4.2.3
Overview table
The meaning of the settings for P1 and P2, depending on the selection of the application is
summarized in the following table.
Instruction
40 -
delay ms
140 -
(retriggerable)
41 -
delay s
141 -
(retriggerable)
42 -
delay min
142 -
(retriggerable)
50 -
delay ms
150 -
(non-retriggerable)
51 -
delay s
151 -
(non-retriggerable)
52 -
delay min
152 -
(non-retriggerable)
60 -
Monoflop ms (retriggerable)
160 -
61 -
Monoflop s (retriggerable)
161 -
62 -
Monoflop min (retriggerable)
162 -
70 -
Monoflop ms (non-retriggerable)
170 -
71 -
Monoflop s (non-retriggerable)
171 -
48
48
Delay
Monoflop
Clock generator
Jump function
Min.
Max.
1
32
1
32
P1
delay pos. edge [ms]
delay pos. edge [s]
delay pos. edge [min]
delay pos. edge [ms]
delay pos. edge [s]
delay pos. edge [min]
ON time [ms]
ON time [s]
ON time [min]
ON time [ms]
ON time [s]
VPLC / PLC
VPLC / PLC
P2
delay neg. edge [ms]
delay neg. edge [s]
delay neg. edge [min]
delay neg. edge [ms]
delay neg. edge [s]
delay neg. edge [min]
ignore edge time [ms]
ignore edge time [s]
ignore edge time [min]
ignore edge time [ms]
ignore edge time [s]
08/10
08/10