Analog switch
Analog multip-
390 -
lexer
Analog chan-
391 -
geover switch
Analog multip-
lexer for posi-
392 -
tion values
(data set num-
ber)
Analog chan-
geover switch
393 -
for position
values
Parameter access (reading and writing parameters)
Writing fre-
401 -
quency para-
meters
Write current
402 -
parameter
Write voltage
403 -
parameter (eff.)
Write voltage
404 -
parameter
(peak)
Write percent
405 -
parameter
Write position
406 -
parameter
Write long pa-
407 -
rameter
Write word
408 -
parameter
Read frequency
421 -
parameter
Read current
422 -
parameter
Read voltage
423 -
parameter
(eff.)
Read voltage
424 -
parameter
(peak)
Read percent
425 -
parameter
Read position
426 -
parameter
Read long pa-
427 -
rameter
Read word
428 -
parameter
08/10
08/10
One of the values I1, I2, P1 or P2 is output. See chapter 5.6.2.
Depending on the active data set, one of the input values (I1 ... I4) is
output. See chapter 5.6.1.
One of the values I1, I2, or P (P1|P2) is output. See chapter 5.6.3
Depending on the active data set, one of the input values (I1 ... I4) is
output. See chapter 5.6.4.
The input value is converted from percent to Hz and written as long
parameter. See chapter 5.7.1.1.
The input value is converted from percent to A and written as int
parameter. See chapter 5.7.1.2.
The effective value at the input is converted from percent to V and
written as int parameter. See chapter 5.7.1.3.
The peak value at the input is converted from percent to V and writ-
ten as int parameter. See chapter 5.7.1.4.
The input value is not changed and written as int parameter. See
chapter 5.7.1.5.
The input value is not changed and written as long parameter. See
chapter 5.7.1.6.
The input value is put together from of low-word and high-word, not
changed and output as long parameter. For use for any long parame-
ter types. See chapter 5.7.1.7.
The input value is not changed and written as int parameter. See
chapter 5.7.1.8.
The function reads the value of the parameter set up in P1 "Parame-
ter number" and P2 "Data set/index". The value is converted to a
frequency value. See chapter 5.7.2.1
The function reads the value of the parameter set up in P1 "Parame-
ter number" and P2 "Data set/index". The value is converted to a
current value. See chapter 5.7.2.2
The function reads the value of the parameter set up in P1 "Parame-
ter number" and P2 "Data set/index". The value is converted to a
voltage value. See chapter 5.7.2.3
The function reads the value of the parameter set up in P1 "Parame-
ter number" and P2 "Data set/index". The value is converted to a
voltage value See chapter 5.7.2.4
The function reads the value of the parameter set up in P1 "Parame-
ter number" and P2 "Data set/index". The value is converted to a
percent value. See chapter 5.7.2.5
The function reads the value of the parameter set up in P1 "Parame-
ter number" and P2 "Data set/index". The value is converted to a
position value. See chapter 5.7.2.6
The function reads the value of the parameter set up in P1 "Parame-
ter number" and P2 "Data set/index". The value is converted to a
position value. See chapter 5.7.2.7
The function reads the value of the parameter set up in P1 "Parame-
ter number" and P2 "Data set/index". The value is converted to a
percent value. See chapter 5.7.2.8.