X1/X2 motor connection

Table 7- 1
X1/X2 motor connection
For ring cable lugs without insulation
1)
7.3.3

X11/X12 motor brake connection

Table 7- 2
X11/X12 motor brake connection
Terminals
+ (BR+)
- (BR-)
The circuit for protecting the brake against overvoltage is integrated in the Motor Module and does not need to be
1)
installed externally. The max. load current is 2 A, the min. load current 0.1 A.
494
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Terminal
Technical data
U2
Type: Screw terminal 5 (Page 755)
Max. cross-section that can be connected: 6 mm
V2
Tightening torque: 1.2 ... 1.5 Nm
W2
PE connection
Single Motor Modules 3 ... 18 A
Threaded hole M5 / 3 Nm
Double Motor Modules 1.7 ... 5 A
Threaded hole M5 / 3 Nm
Technical data
Brake connector
Voltage 24 V DC
Max. load current 2 A
Min. load current 0.1 A
Max. connectable cross-section 2.5 mm
Type: Spring-loaded terminal 2 (Page 754)
Manufacturer: Wago; order number: 721-102/026-000/56-000
The brake connector is part of the scope of delivery.
1
1
:
1)
2