(C) Motor constant parameters
Setting the applied motor
Refer to the following list and set the parameters according to the applied motor.
Pr. 71
0
(Pr. 71 initial
value)
1
2
20
30
40
50
70
330
8090
9090
3 (4)
13 (14)
23 (24)
33 (34)
43 (44)
53 (54)
73 (74)
333 (334)
8093 (8094)
9093(9094)
Tab. 5-175: Setting of parameter Pr. 71 and Pr. 450 (1)
5 - 452
Pr.
Motor
450
Standard motor (such as SF-JR)
Constant-torque motor
(SF-JRCA, etc.)
SF-V5RU
(other than 1500 r/min series)
Standard motor (such as SF-JR)
Adjustable 5 points V/F
(Refer to page 5-698.)
Mitsubishi standard motor
(SF-JR 4P 1.5 kW or lower)
Vector control dedicated motor
SF-V5RU (1500 r/min series)
SF-THY
Mitsubishi high-efficiency motor
SF-HR
Mitsubishi constant-torque motor
SF-HRCA
Mitsubishi high-performance
energy-saving motor SF-PR
IPM motor MM-CF
IPM motor (other than MM-CF)
SPM motor
Standard motor (such as SF-JR)
Constant-torque motor (SF-JRCA,
etc.)
SF-V5RU (other than 1500 r/min
series)
Mitsubishi standard motor
(SF-JR 4P 1.5 kW or lower)
Vector control dedicated motor
SF-V5RU (1500 r/min series)
SF-THY
Mitsubishi high-efficiency motor
SF-HR
Mitsubishi constant-torque motor
SF-HRCA
Mitsubishi high-performance
energy-saving motor SF-PR
IPM motor MM-CF
IPM motor (other than MM-CF)
SPM motor
Constant value range when
performing offline auto tuning
(increment)
Pr. 82 (Pr. 455) and Pr. 859 (Pr. 860)
0 to 500 A, 9999 (0.01 A)
0 to 3600 A, 9999 (0.1 A)
Pr. 90 (Pr. 458) and Pr. 91 (Pr. 459)
0 to 50 Ω, 9999 (0.001 Ω)
0 to 400 mΩ, 9999 (0.01 mΩ)
Pr. 92 (Pr. 460) and Pr. 93 (Pr. 461)
(Induction motor)
0 to 6000 mH, 9999 (0.1 mH)
0 to 400 mH, 9999 (0.01 mH)
Pr. 92 (Pr. 460) and Pr. 93 (Pr. 461)
(PM motor)
0 to 500 mH, 9999 (0.01 mH)
0 to 50 mH, 9999 (0.001 mH)
Pr. 94 (Pr. 462)
0 to 100%, 9999(0.1%)
0 to 100%, 9999(0.01%)
Pr. 706 (Pr. 738)
0 to 5000 mV/(rad/s), 9999
(0.1 mV/(rad/s))
Pr. 82 (Pr. 455), Pr. 859 (Pr. 860),
Pr. 90 (Pr. 458), Pr. 91 (Pr. 459),
Pr. 92 (Pr. 460), Pr. 93 (Pr. 461),
Pr. 94 (Pr. 462) and Pr. 706 (Pr. 738)
Internal data value 0 to 65534,
9999 (1)
The display increment can be
changed in Pr. 684.
Parameters
Operational characteristic
of the electronic thermal O/L
relay
Stand-
Constant
PM
ard
-torque