5.21.2

I/O signal list

Remote I/O (64 points (fixed))
Device No.
Signal
RYn0
Forward rotation command
RYn1
Reverse rotation command
High-speed operation command
RYn2
(terminal RH function)
Middle-speed operation command
RYn3
(terminal RM function)
Low-speed operation command
RYn4
(terminal RL function)
Jog operation command
RYn5
(terminal Jog function)
Second function selection
RYn6
(terminal RT function)
RYn7
Current input selection (terminal AU function)
Selection of automatic restart after instanta-
RYn8
neous power failure (terminal CS function)
RYn9
Output stop (terminal MRS function)
Start self-holding selection
RYnA
(terminal STOP function)
RYnB
Reset (terminal RES function)
RYnC
to
RYnF
Reserved
RY(n+1)0 to
RY(n+1)2
RY(n+1)3 to
Reserved
RY(n+1)F
RY(n+2)0 Monitor command
RY(n+2)1 Frequency setting command (RAM)
RY(n+2)2 Frequency setting command (RAM, EEPROM)
RY(n+2)3 Torque command / torque limit (RAM)
RY(n+2)4 Torque command / torque limit (RAM, EEPROM)
RY(n+2)5 Instruction code execution request
RY(n+2)6 to
Reserved
RY(n+3)9
RY(n+3)A Error reset request flag
RY(n+3)B to
Reserved
RY(n+3)F
Tab. 5-342:
Remote output signals
These signals are set in the initial values. Using Pr. 180 to Pr. 189, input signal functions can be
changed (refer to page 5-439).
The signals are fixed. They cannot be changed using parameters.
These signals are set in the initial values. Using Pr. 190 to Pr. 196, output signal functions can be
changed (refer to page 5-378).
Output signal can be assigned using Pr. 313 to Pr. 315 (refer to page 5-378).
"n" indicates a value determined by the station number setting.
FR-A800
Refer to
Device No.
Signal
page
5-752
RXn0
Forward running
5-752
RXn1
Reverse running
RXn2
5-752
Running (terminal RUN function)
RXn3
Up to frequency (terminal SU function)
5-752
RXn4
Overload alarm (terminal OL function)
Instantaneous power failure
5-752
RXn5
(terminal IPF function)
RXn6
Frequency detection (terminal FU function)
5-752
RXn7
Error (terminal ABC1 function)
5-752
RXn8
— (terminal ABC2 function)
5-752
RXn9
to
Reserved
5-752
RXnF
RX(n+1)0 Pr. 313 assignment function (DO0)
5-752
RX(n+1)1 Pr. 314 assignment function (DO1)
5-752
RX(n+1)2 Pr.315 assignment function (DO2)
5-752
RX(n+1)3 to
Reserved
RX(n+1)F
5-752
RX(n+2)0 Monitoring
RX(n+2)1 Frequency setting completion (RAM)
5-752
RX(n+2)2 Frequency setting completion (RAM, EEPROM)
Torque command / torque limit setting
5-752
RX(n+2)3
completion (RAM)
5-752
Torque command / torque limit setting
RX(n+2)4
completion (RAM, EEPROM)
5-752
RX(n+2)5 Instruction code execution completion
5-752
RX(n+2)6 to
5-752
Reserved
RX(n+3)9
5-752
RX(n+3)A Error status flag
5-752
RX(n+3)B Remote station ready
5-752
RX(n+3)C to
Reserved
RX(n+3)F
5-752
Tab. 5-343:
5-752
CC-Link IE Field Network (FR-A800-GF)
Remote input signals
Refer to
page
5-753
5-753
5-753
5-753
5-753
5-753
5-753
5-753
5-753
5-753
5-753
5-753
5-753
5-753
5-753
5-753
5-753
5-753
5-753
5-753
5-753
5-753
5-753
5-753
5 - 749