Parameters
5.8.6

Shortest acceleration/deceleration and optimum acceleration/deceleration

(automatic acceleration/deceleration)
The inverter can be operated with the same conditions as when the appropriate value is set to each
parameter even when acceleration/deceleration time and V/F pattern are not set. This function is use-
ful for operating the inverter without setting detailed parameters.
Pr.
292
F500
61
F510
62
F511
63
F512
293
F513
The setting range for the FR-A820-03160(55K) or lower and FR-A840-01800(55K) or lower.
The setting range for the FR-A820-03800(75K) or higher and FR-A840-02160(75K) or higher.
FR-A800
(F) Setting of acceleration/deceleration time and acceleration/deceleration pattern
Name
Automatic acceleration/
deceleration
Reference current
Reference value at acceleration
Reference value at deceleration
Acceleration/deceleration
separate selection
V/F
V/F
V/F
Magnetic flux
Magnetic flux
Magnetic flux Sensorless
Initial
Setting range
Description
value
0
Normal operation
Shortest acceleration/deceleration
1
(without brakes)
Shortest acceleration/deceleration (with
11
brakes)
0
3
Optimum acceleration/deceleration
Lift operation 1, 2
5, 6
(Refer to page 5-268.)
7, 8
Brake sequence 1, 2 (Refer to page 5-501.)
0 to 500 A
Set the reference current during shortest
(optimum) acceleration/deceleration.
0 to 3600 A
9999
Rated output current value reference of
9999
the inverter
Set the speed limit value (optimum value)
0 to 220%
during shortest (optimum) acceleration.
Shortest acceleration/deceleration:
9999
150% as the limit value
9999
Optimum acceleration/deceleration:
100% as the optimum value
Set the speed limit value (optimum value)
0 to 220%
during shortest (optimum) deceleration.
Shortest acceleration/deceleration:
9999
150% as the limit value
9999
Optimum acceleration/deceleration:
100% as the optimum value
Shortest (optimum) acceleration/
0
deceleration for both acceleration and
deceleration
0
Shortest (optimum) acceleration/
1
deceleration for acceleration only
Shortest (optimum) acceleration/
2
deceleration for deceleration only
Sensorless Vector
Sensorless
Vector
Vector
5 - 263