Advertisement

Parameters
● When Pr. 544 = "12" (compatible with the double setting of CC-Link Ver.2)
– Remote I/O (32 points)
Same as when Pr. 544 = 0 (refer to page 5-805).
– Remote register
Description
Address
Upper 8 bits
RWwn
Monitor code 2
Set frequency (0.01 Hz increments) /
RWwn+1
torque command
Link parameter
RWwn+2
extended setting
RWwn+3
RWwn+4
Monitor code 3
RWwn+5
Monitor code 4
RWwn+6
Monitor code 5
RWwn+7
Monitor code 6
Tab. 5-395:
Remote registers (write)
When Pr. 804 ="3 or 5" during torque control under Real sensorless vector control or vector control,
a torque command value is set in RWwn+1.
"n" indicates a value determined by the station number setting.
FR-A800
Refer to
Lower 8 bits
Monitor code 1
Instruction code
Write data
Address
page
Upper 8 bits
5-812
RWrn
RWrn+1
5-812
RWrn+2
5-812
RWrn+3
5-812
RWrn+4
5-812
RWrn+5
5-812
RWrn+6
5-812
RWrn+7
5-812
Tab. 5-396:
Ethernet communication (FR-A800-E)
Description
Lower 8 bits
First monitor value
Second monitor value
Reply code 2
Reply code 1
Read data
Third monitor value
Fourth monitor value
Fifth monitor value
Sixth monitor value
Remote registers (read)
Refer to
page
5-814
5-814
5-814
5-814
5-814
5-814
5-814
5-814
5 - 807