Basic operation
4.3
Easy operation mode setting (easy setting mode)
A required combination of a start command and a frequency command can be easily selected using
Pr. 79 "Operation mode selection".
Example
Changing example:
Operate with the external (STF/STR) start command and setting dial frequency command.
Press
Turn
operation mode 1) appears.
(For other settings, refer to the table below.)
Press
combined operation mode 1 (Pr. 79 = "3") is set.
Tab. 4-6:
Flickering
Flickering
Flickering
Flickering
Tab. 4-7:
To use the setting dial as a potentiometer, refer to page 5-206.
FR-A800
and
for 0.5 s.
until
(External/PU combined
to enter the setting. External/PU
One can immediately change parameter 79 by simultaneously pressing the PU/EXT and
MODE keys
Operation panel indication
Operation modes and operation panel indication
Easy operation mode setting (easy setting mode)
Operation
Flickering
Flickering
Operation method
Frequency
Start command
command
,
External
Analog
(STF, STR)
voltage input
External
(STF, STR)
Analog
voltage input
,
Operation mode
PU operation mode
External operation mode
External/PU combined
operation mode 1
External/PU combined
operation mode 2
4 - 9