Mitsubishi Electric FR-A820-00046 Instruction Manual page 869

Fr-a800 series
Hide thumbs Also See for FR-A820-00046:
Table of Contents

Advertisement

Parameters
Bit
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Tab. 5-301: Inverter status/control input command
The signal within parentheses ( ) is the initial status. The description changes depending on the
setting of Pr. 180 to Pr. 189 (input terminal function selection) (page 5-439).
For each of the assigned signals, some signals are enabled by NET and some are disabled. (Refer
to page 5-289.)
The inverter run enable signal is in the initial status for the separated converter type.
The signal within parentheses ( ) is the initial status. The description changes depending on the
setting of Pr. 190 to Pr. 196 (output terminal function selection) (page 5-378).
No function is assigned in the initial status for the separated converter type.
Tab. 5-302: Operation mode/inverter setting
Enable/disable parameter writing by Pr. 79 and Pr. 340 settings. For the details, refer to page 5-280.
Restrictions in each operation mode conform with the computer link specification.
● Real-time monitor
Refer to page 5-344 for the register numbers and monitored items of the real time monitor.
FR-A800
Control input command
Stop command
Forward rotation command
Reverse rotation command
RH (High-speed operation command)
RM (Middle-speed operation command)
RL (Low-speed operation command)
JOG (Jog operation selection)
RT (Second function selection)
AU (Terminal 4 input selection)
CS (Selection of automatic restart after instantaneous
power failure, flying start)
MRS (Output stop)
STP (STOP) (Start self-holding selection)
RES (Inverter reset)
0
0
0
Mode
EXT
PU
EXT
JOG
PU
JOG
NET
PU+EXT
(N) Operation via communication and its settings
Definition
Inverter status
RUN (Inverter running)
During forward rotation
During reverse rotation
SU (Up to frequency)
OL (Overload warning)
IPF (Instantaneous power failure/undervoltage)
FU (Output frequency detection)
ABC1 (Fault)
ABC2 (⎯)
Safety monitor output
0
0
0
0
0
Fault occurrence
Read value
H0000
H0001
H0002
H0003
H0004
H0005
Write value
H0010
H0011
H0014
5 - 667

Hide quick links:

Advertisement

Table of Contents
loading