Mitsubishi Electric FR-A820-00046 Instruction Manual page 438

Fr-a800 series
Hide thumbs Also See for FR-A820-00046:
Table of Contents

Advertisement

(E) Environment setting parameters
NOTES
The Y95 signal turns ON when any of MT1, MT2 or MT3 is activated. It does not turn OFF unless all
of MT1, MT2 and MT3 are cleared.
If all of MT1, MT2 and MT3 are activated, they are displayed in the priority of "MT1 > MT2 > MT3".
The cumulative energization time is counted every hour. Energization time of less than 1 h is not
counted.
Changing the terminal assignment using Pr. 190 to Pr. 196 (output terminal function selection)
may affect the other functions. Set parameters after confirming the function of each terminal.
Parameters referred to
Pr. 190 to Pr. 196
5 - 236
(output terminal function selection)
Parameters
=>
page 5-378

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents