Mitsubishi Electric FR-A820-00046 Instruction Manual page 1007

Fr-a800 series
Hide thumbs Also See for FR-A820-00046:
Table of Contents

Advertisement

Parameters
I/O signal list
● When Pr. 544 = "0" (compatible with CC-Link Ver.1)
– Remote I/O (32 points)
Device No.
Signal
RYn0
Forward rotation command
RYn1
Reverse rotation command
High-speed operation command
RYn2
(terminal RH function)
Middle-speed operation command
RYn3
(terminal RM function)
Low-speed operation command
RYn4
(terminal RL function)
Jog operation command
RYn5
(terminal Jog function)
Second function selection
RYn6
(terminal RT function)
RYn7
Current input selection (terminal AU function)
Selection of automatic restart after instanta-
RYn8
neous power failure (terminal CS function)
RYn9
Output stop (terminal MRS function)
Start self-holding selection
RYnA
(terminal STOP function)
RYnB
Reset (terminal RES function)
RYnC
Monitor command
RYnD
Frequency setting command (RAM)
RYnE
Frequency setting command (RAM, EEPROM)
RYnF
Instruction code execution request
RY(n+1)0 to
Reserved
RY(n+1)7
RY(n+1)8 Not used (initial data process completion flag)
RY(n+1)9 Not used (initial data process request flag)
RY(n+1)A Error reset request flag
RY(n+1)B to
Reserved
RY(n+1)F
Tab. 5-389:
Remote output signals
These signals are set in the initial values. Using Pr. 180 to Pr. 189, input signal functions can be
changed (refer to page 5-439).
The signals are fixed. They cannot be changed using parameters.
These signals are set in the initial values. Using Pr. 190 to Pr. 196, output signal functions can be
changed (refer to page 5-378).
Output signal can be assigned using Pr. 313 to Pr. 315. The setting range depends on the inverter.
Using Pr. 190 to Pr. 196, output signal functions can be changed (refer to page 5-378).
"n" indicates a value determined by the station number setting.
FR-A800
Refer to
Device No.
Signal
page
5-810
RXn0
Forward running
5-810
RXn1
Reverse running
RXn2
5-810
Running (terminal RUN function)
RXn3
Up to frequency (terminal SU function)
5-810
RXn4
Overload alarm (terminal OL function)
Instantaneous power failure
5-810
RXn5
(terminal IPF function)
RXn6
Frequency detection (terminal FU function)
5-810
RXn7
Error (terminal ABC1 function)
5-810
RXn8
— (terminal ABC2 function)
5-810
RXn9
Pr. 313 assignment function (DO0)
RXnA
Pr. 314 assignment function (DO1)
5-810
RXnB
Pr. 315 assignment function (DO2)
5-810
RXnC
Monitoring
5-810
RXnD
Frequency setting completion (RAM)
5-810
RXnE
Frequency setting completion (RAM, EEPROM)
5-810
RXnF
Instruction code execution completion
5-810
RX(n+1)0 to
Reserved
RX(n+1)7
5-810
RX(n+1)8 Not used (initial data process request flag)
5-810
RX(n+1)9 Not used (initial data process completion flag)
RX(n+1)A Error status flag
RX(n+1)B Remote station ready
RX(n+1)C to
Reserved
5-810
RX(n+1)F
Tab. 5-390:
Ethernet communication (FR-A800-E)
Remote input signals
Refer to
page
5-811
5-811
5-811
5-811
5-811
5-811
5-811
5-811
5-811
5-811
5-811
5-811
5-811
5-811
5-811
5-811
5-811
5-811
5 - 805