Mitsubishi Electric FR-A820-00046 Instruction Manual page 460

Fr-a800 series
Hide thumbs Also See for FR-A820-00046:
Table of Contents

Advertisement

(F) Setting of acceleration/deceleration time and acceleration/deceleration pattern
The multi-speed operation function is invalid when remote setting function is selected.
Setting frequency is "0".
Even when the remotely-set frequency is cleared by turning ON the RL (clear) signal after turning
OFF (ON) both the RH and RM signals, the inverter operates at the remotely-set frequency stored
in the last operation if power is reapplied before one minute has elapsed since turning OFF (ON)
both the RH and RM signals.
When the remotely-set frequency is cleared by turning ON the RL (clear) signal after turning OFF
(ON) both the RH and RM signals, the inverter operates at the frequency in the remotely-set fre-
quency cleared state if power is reapplied before one minute has elapsed since turning OFF (ON)
both the RH and RM signals.
CAUTION:
E
When using the remote setting function, set the maximum frequency again according to the
machine.
Parameters referred to
Pr. 1
Pr. 18
Pr. 7
Pr. 8
Pr. 44
Pr. 45
Pr. 28
Pr. 178 to Pr. 182
5 - 258
Remotely-set frequency stored last time
Acceleration RH
ON
Deceleration RM
OFF
Clear RL
Forward rotation STF
Power supply
Remotely-set frequency stored last time
ON
Acceleration RH
OFF
Deceleration RM
Clear RL
Forward rotation STF
Power supply
Maximum frequency
High speed maximum frequency
Acceleration time
Deceleration time
Second acceleration/deceleration time
Second deceleration time
Multi-speed input compensation selection
(input terminal function selection)
< 1 minute
Remotely-set frequency stored last time
ON
ON
ON
ON
ON
1 minute
> 1 minute
Operation is performed at the
set frequency 0 Hz.
ON
ON
ON
ON
ON
Time
Time
=>