During Communication Operation - Mitsubishi Electric FR-A820-00046 Instruction Manual

Fr-a800 series
Hide thumbs Also See for FR-A820-00046:
Table of Contents

Advertisement

(D) Operation command and frequency command
5.9.3
Start command source and frequency command source during communication
operation
The start and frequency commands from an external device can be made valid when using the RS-485
terminals or the communication option. The command source in the PU operation mode can also be
selected.
For FR-A800-E: When the Ethernet connector or a communication option is used, the command
source in the network (NET) / PU operation mode can be selected.
Pr.
338
D010
339
D011
550
D012
551
D013
5 - 282
Name
Communication operation
command source
Communication speed command
source
NET mode operation command
source selection
PU mode operation command
source selection
Initial value
Setting range
0
0
1
0
1
0
2
0
1
5
9999
9999
1
2
9999
3
5
9999
Parameters
Description
Start command source is
communication.
Start command source is external.
Frequency command source is
communication.
Frequency command source is
external.
Frequency command source is
external. (When there is no external
input, the frequency command via
communication is valid, and the
frequency command from terminal 2
is invalid.)
The communication option is the
command source when in the NET
operation mode.
The RS-485 terminals are the
command source when in the NET
operation mode.
FR-A800-E: For manufacturer setting.
Do not set.
FR-A800-E: The Ethernet connector is
the command source when in the
NET operation mode.
Communication option is recognized
automatically.
Normally, the RS-485 terminals are
the command source.
FR-A800-E: The Ethernet connector is
the command source.
When the communication option is
mounted, the communication
option is the command source.
The RS-485 terminals are the
command source when in the PU
operation mode.
FR-A800-E: For manufacturer setting.
Do not set.
The PU connector is the command
source when in the PU operation
mode.
The USB connector is the command
source when in the PU operation
mode.
FR-A800-E: The Ethernet connector is
the command source when in the PU
operation mode.
USB automatic recognition
Normally, the PU connector is the
command source. When the USB is
connected, the USB connector is the
command source.

Hide quick links: