(N) Operation via communication and its settings
Pr.
1432
N644
1424
N650
1425
N651
1442
N660
1443
N661
1444
N662
1445
N663
1446
N664
1447
N665
1448
N666
1449
N670
1450
N671
1451
N672
1452
N673
1453
N674
1454
N675
The setting is applied after an inverter reset or power-ON.
NOTE
The monitored items and parameter settings can be read during communication with the Pr.1432
Ethernet communication check time interval = "0" setting, but an inverter fault occurs instantly
when the operation mode is switched to the NET operation mode. When the NET operation mode
is selected as the start-up operation mode, communication is performed once, then an Ethernet
communication fault (E.EHR) occurs.
To perform operation or parameter writing via communication, set Pr.1432 to "9999" or a value
larger than the communication cycle or retry time setting (refer to page 5-682).
5 - 676
Name
Ethernet communication
check time interval
Ethernet communication
network number
Ethernet communication
station number
Ethernet IP filter address 1
Ethernet IP filter address 2
Ethernet IP filter address 3
Ethernet IP filter address 4
Ethernet IP filter address 2
range specification
Ethernet IP filter address 3
range specification
Ethernet IP filter address 4
range specification
Ethernet command source
selection IP address 1
Ethernet command source
selection IP address 2
Ethernet command source
selection IP address 3
Ethernet command source
selection IP address 4
Ethernet command source
selection IP address 3 range
specification
Ethernet command source
selection IP address 4 range
specification
Initial
Setting range
Description
value
Ethernet communication is available, but the
0
inverter trips in the NET operation mode.
Set the interval of the communication check
(signal loss detection) time for all devices with IP
addresses in the range specified for Ethernet
9999
0.1 to 999.8 s
command source selection (Pr. 1449 to Pr. 1454).
If a no-communication state persists for the
permissible time or longer, the inverter will trip.
9999
No communication check (signal loss detection)
1
1 to 120
Enter the network number.
1
1 to 120
Enter the station number.
0
0 to 255
0
0 to 255
0
0 to 255
Set the range of connectable IP addresses for the
network devices.
0
0 to 255
(When Pr. 1442 to Pr. 1445 = "0 (initial value)", the
function is invalid.)
9999
0 to 255, 9999
9999
0 to 255, 9999
9999
0 to 255, 9999
To limit the network devices that send the
0
0 to 255
operation or speed command through the
Ethernet network (Modbus®/TCP or CCLink IE
Field Network Basic), set the range of IP addresses
0
0 to 255
of the devices. When Pr. 1449 to Pr. 1452 = "0
(initial value)", no IP address is specified for
0
0 to 255
sending commands through the Ethernet
network.
0
0 to 255
In this case, operation through the Ethernet
network (Modbus®/TCP or CC-Link IE Field
Network Basic) is not available. When four or
9999
0 to 255, 9999
more clients attempt a connection to the inverter
during Modbus®/TCP communication, the
connection attempted from outside of the IP
address range set for Ethernet command source
9999
0 to 255, 9999
selection may be forced to be closed.
Parameters