Ethernet communication (FR-A800-E)
Example
Read the register values of 41004 (Pr. 4) to 41006 (Pr. 6) from slave address 17 (H11).
Query message
Transaction
identifier
A given value is set.
Normal response (Response message)
Transaction
identifier
The values are the same as those in the query message.
Read value
Register 41004 (Pr. 4): H1770 (60.00 Hz)
Register 41005 (Pr. 5): H0BB8 (30.00 Hz)
Register 41006 (Pr. 6): H03E8 (10.00 Hz)
5 - 790
Protocol
Length field
Identifier
H00
H00
H00
(8 bits)
(8 bits)
(8 bits)
Protocol
Length field
Identifier
H00
H00
H00
H09
(8 bits)
(8 bits)
(8 bits)
(8 bits)
Func-
Unit identifier
tion
H06
H11
H03
(8 bits)
(8 bits)
(8 bits)
Unit
Func-
Byte
identi-
tion
count
fier
H11
H03
H06
H17
(8 bits)
(8 bits)
(8 bits)
(8 bits)
Parameters
Starting address
No. of points
H03
HEB
H00
(8 bits)
(8 bits)
(8 bits)
Data
H70
H0B
HB8
H03
(8 bits)
(8 bits)
(8 bits)
(8 bits)
H03
(8 bits)
HE8
(8 bits)