Mitsubishi Electric FR-A820-00046 Instruction Manual page 1013

Fr-a800 series
Hide thumbs Also See for FR-A820-00046:
Table of Contents

Advertisement

Parameters
● Input signals (inverter to master module)
Device No.
Signal
RX0
Forward running
RX1
Reverse running
RX2
Running (terminal RUN function)
RX3
Up to frequency (terminal SU function)
RX4
Overload alarm (terminal OL function)
Instantaneous power failure (terminal
RX5
IPF function)
Frequency detection (terminal FU
RX6
function)
RX7
Fault (terminal ABC1 function)
RX8
— (terminal ABC2 function)
RX9
— (DO0 function)
RXA
— (DO1 function)
RXB
— (DO2 function)
RXC
Monitoring
Frequency setting completion / torque
RXD
command setting completion (RAM)
Frequency setting completion /
RXE
torque command setting completion
(RAM, EEPROM)
RXF
Instruction code execution completion
RX1A
Error status flag
RX1B
Remote station ready
Tab. 5-402:
Output signals from the inverter (input signals to master module)
FR-A800
Description
0 : Other than forward running (during stop or reverse rotation)
1 : Forward running
0 : Other than reverse running (during stop or forward rotation)
1 : Reverse running
Functions assigned to terminals RUN, SU, OL, IPF, FU, ABC1 and ABC2 activate.
Signal names are initial values. Using Pr. 190 to Pr. 196, you can change output
signal functions.
Functions assigned to Pr. 313 to Pr. 315 are activated.
No signal is assigned in the initial setting. Use Pr.313 to Pr.315 to assign signals to
the devices RX9 to RXB. The setting range depends on the inverter. For details,
refer to the description of Pr. 190 to Pr. 196 (Output terminal function selection)
on page 5-378.
After "1" is set in the monitor command (RYC), and the monitored value is set in the
remote register Rwr0, 1, 4 to 7,, "1" is set in this signal. When "0" is set in the monitor
command (RYC), "0" is set in this signal.
After "1" is set in the frequency setting command/torque command (RYD) and the
frequency setting command/torque command is written to the inverter RAM, "1" is
set in this signal.
When "0" is set in the frequency setting command /torque command (RYD), "0" is set
in this signal.
After "1" is set in the frequency setting command/torque command (RYE) and the set
frequency is written to the inverter RAM and EEPROM, "1" is set in this signal.
When "0" is set in the frequency setting command/torque command (RYE), "0" is set in
this signal.
After "1" is set in the instruction code execution request (RYF) and the processes
corresponding to the instruction codes (RWw2, 10, 12, 14, 16, and 18) are executed,
"1" is set in this signal. When "0" is set in the instruction code execution request (RYF),
"0" is set in this signal.
When an inverter error occurs (protective function is activated), "1" is set in this signal.
When the inverter goes into the ready status upon completion of initial setting after
power-ON or hardware reset, "1" is set in this signal. When an inverter error occurs
(protective function is activated), "0" is set in this signal. The signal is used as an
interlock signal during the write to/read from the master module.
Ethernet communication (FR-A800-E)
5 - 811

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents