Mitsubishi Electric FR-A820-00046 Instruction Manual page 1116

Fr-a800 series
Hide thumbs Also See for FR-A820-00046:
Table of Contents

Advertisement

Motor rating
400 V class
Motor type SF-V5RUH K
Applicable inverter model
FR-A840- K (ND rating)
Rated output [kW]
Rated current [A]
Rated torque [Nm]
Maximum torque 150% 60s
[Nm]
Rated speed [r/min]
Maximum speed [r/min]
Frame No.
-4
Inertia moment J [×10
kg× m
Noise
Voltage
Cooling fan
(with thermal
Input
protector)
Recommended
thermal setting
Surrounding air temperature,
humidity
Structure (Protective structure)
Detector
Equipment
Heat resistance class
Vibration rank
Approx. mass [kg]
Tab. 8-5:
Motor rating SF-V5RU (400 V)
80% output in the high-speed range. (The output is reduced when the speed is 2400 r/min or more.
Contact us separately for details.)
A dedicated motor of 3.7 kW or less can be run at the maximum speed of 3600 r/min. Consult our
sales office when using the motor at the maximum speed.
Power (current) at 50 Hz/60 Hz.
Since a motor with brake has a window for gap check, the protective structure of both the cooling
fan section and brake section is IP20. S of IP23S is an additional code indicating the condition that
protection from water intrusion is established only when a cooling fan is not operating.
The value when high carrier frequency is set (Pr. 72 = 6, Pr. 240 = 0).
The 12 V/24 V power supply is required as the power supply for the encoder. (When the FR-A8TP
is used, the 24 V power supply of the FR-A8TP can be used for the encoder of the SF-V5RU.)
The cooling fan is equipped with a thermal protector. The cooling fan stops when the coil
temperature exceeds the specified value in order to protect the fan motor. A restrained cooling
fan or degraded fan motor insulation could be causes for the rise in coil temperature.The cooling
fan re-starts when the coil temperature drops to normal.
The cooling fan voltage and input values are the basic specifications of the cooling fan alone and
free air values. The input value becomes slightly larger when it is rotated by this motor due to an
increased workload, but the cooling fan can be used as it is.When preparing a thermal relay at the
user side, use the recommended thermal setting.
8 - 6
1
2
3
5
2.2
2.2
3.7
7.5
1.5
2.2
3.7
5.5
4.2
5.8
8.8
14.5
9.55
14.1
23.6
35.0
14.3
21.1
35.4
52.4
90L
100L 112M 132S 132M 160M 160L
2
] 67.5
105
175
275
Single-phase 200 V/50 Hz
Single-phase 200 V to 230 V/60 Hz
36/55 W
22/28 W
(0.26/0.32 A)
(0.11/0.13 A)
0.36 A
0.18 A
-10 to +40 °C (non-freezing), 90% RH or less (non-condensing)
Totally enclosed forced draft system (Motor: IP44, cooling fan: IP23S)
Encoder 2048P/R, A phase, B phase, Z phase +12 V/24 V DC power supply
24
33
41
52
7
11
15
18
11
15
18.5
22
7.5
11
15
18.5
18.5
27.5
35.5
44
47.7
70.0
95.5
118
71.6
105
143
176
1500
3000
180M
400
750
875
1725
75 dB
Three-phase 380 to 400 V/50 Hz
Three-phase 400 to 460 V/60 Hz
55/71 W
(0.19/0.19 A)
0.25 A
Encoder, thermal protector, fan
F
V10
62
99
113
138
22
30
37
45
30
37
45
55
22
30
37
45
51
67
84
99
140
191
235
286
211
287
353
429
180M
200L
200L
200L
1875
3250
3625
3625
80 dB
100/156 W
(0.27/0.30 A)
0.39 A
160
238
255
255
Specifications
55
75
55
132
350
525
2400
225S
6850
85 dB
85/130 W
(0.23/0.26 A)
0.34 A
320

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents