Parameters
5.8
(F) Setting of acceleration/deceleration time and

acceleration/deceleration pattern

Purpose
To set the motor acceleration/
deceleration time
To set the acceleration/deceleration
pattern suitable for application
To command smooth speed transition
with terminals
To set the starting frequency
To set optimum acceleration/
deceleration time automatically
To set V/F pattern for lift automatically
5.8.1

Setting the acceleration and deceleration time

The following parameters are used to set motor acceleration/deceleration time.
Set a larger value for a slower acceleration/deceleration, and a smaller value for a faster acceleration/
deceleration.
For the acceleration time at automatic restart after instantaneous power failure, refer to Pr. 611 "Ac-
celeration time at a restart" (page 5-581, page 5-590).
Pr.
20
F000
21
F001
16
F002
611
F003
7
F010
8
F011
44
F020
FR-A800

(F) Setting of acceleration/deceleration time and acceleration/deceleration pattern

Name
Acceleration/deceleration
60 Hz
reference frequency
Acceleration/deceleration
time increments
Jog acceleration/
deceleration time
Acceleration time at a
restart
Acceleration time
Deceleration time
Second acceleration/
deceleration time
Parameter to set
Acceleration/deceleration
time
Acceleration/deceleration
pattern and backlash
measures
Remote setting function
Starting frequency and start-
time hold
Automatic acceleration/
deceleration
Lift operation
(Automatic acceleration/
deceleration)
Initial value
Setting range
FM
CA
50 Hz
1 to 590 Hz
0
0
1
0.5 s
0 to 3600 s
9999
0 to 3600 s, 9999
5 s
0 to 3600 s
15 s
5 s
0 to 3600 s
15 s
5 s
0 to 3600 s
P.F000 to P.F003,
Pr. 7, Pr. 8, Pr. 16,
P.F010, P.F011,
Pr. 20, Pr. 21, Pr. 44,
P.F020 to P.F022,
Pr. 45, Pr. 110,
P.F030, P.F031,
Pr. 111, Pr. 147,
P.F040, P.F070,
Pr. 611, Pr. 791,
P.F071
Pr. 792, Pr.1103
P.F100,
Pr. 29,
P.F200 to P.F203,
Pr. 140 to Pr. 143,
P.F300 to P.F303,
Pr. 380 to Pr. 383,
P.F400 to P.F403
Pr. 516 to Pr. 519
P.F101
Pr. 59
P.F102, P.F103
Pr. 13, Pr. 571
P.F500,
Pr. 61 to Pr. 63,
P.F510 to P.F513
Pr. 292
P.F500, P.F510,
Pr. 61, Pr. 64,
P.F520
Pr. 292
Description
Set the frequency that will be the basis of
acceleration/deceleration time. As
acceleration/deceleration time, set the
frequency change time from a stop status
to Pr. 20.
Select the increment
Increment: 0.1 s
for the acceleration/
deceleration time
Increment: 0.01 s
setting and the
setting range.
Set the acceleration/deceleration time for
JOG operation (from stop status to Pr. 20).
Refer to page 5-296
Set the acceleration time for restart (from
stop status to Pr. 20).
When "9999" is set, standard acceleration
time (like Pr. 7) is applied as the
acceleration time at restart.
Refer to page 5-581, page 5-590.
Set the motor acceleration time (from
stop status to Pr. 20).
Set the motor deceleration time (from
Pr. 20 to stop status).
Set the acceleration/deceleration time
when the RT signal is ON.
Refer to
page
5-241
5-248
5-255
5-259,
5-261
5-263
5-268
5 - 241