Perform a manual PW switchover.

Configuring static PW redundancy

Step
1.
Enter system view.
2.
Enter VSI view.
3.
Specify static signaling for
PWs, and enter VSI static
view.
4.
(Optional.) Specify the
switchover mode and set the
wait time for the switchover.
5.
Configure a static PW and
enter VSI static PW view.
6.
Configure a backup static PW
and enter VSI static backup
PW view.
7.
Return to user view.
8.
Manually switch traffic of the
specified PW to its backup
PW.
Configuring LDP PW redundancy
Step
1.
Enter system view.
2.
Enter VSI view.
3.
Specify LDP signaling for
PWs, and enter VSI LDP
signaling view.
4.
(Optional.) Specify the
switchover mode and set the
wait time for the switchover.
Command
system-view
vsi vsi-name [ hub-spoke ]
pwsignaling static
revertive { wtr wtr-time | never }
peer ip-address [ pw-id pw-id ]
[ in-label label-value out-label
label-value ] [ hub |
no-split-horizon | pw-class
class-name | tunnel-policy
tunnel-policy-name ] *
backup-peer ip-address [ pw-id
pw-id ] in-label label-value
out-label label-value [ pw-class
class-name | tunnel-policy
tunnel-policy-name ] *
return
l2vpn switchover peer
ip-address pw-id pw-id
Command
system-view
vsi vsi-name [ hub-spoke ]
pwsignaling ldp
revertive { wtr wtr-time | never }
453
Remarks
N/A
N/A
By default, no PW signaling
protocol is specified for the VSI.
By default, the switchover mode is
revertive and the switchover wait
time is 0 seconds.
By default, no static PWs exist.
By default, no backup static PW
exists.
If both the default PW ID in the
default-pw-id command and a
PW ID in the backup-peer
command are configured, the PW
ID in the backup-peer command
is used. If only the default PW ID is
configured, the default PW ID is
used. If no default PW ID is
configured, you must provide a
PW ID in the backup-peer
command.
N/A
N/A
Remarks
N/A
N/A
By default, no PW signaling
protocol is specified for the VSI.
By default, the switchover mode
is revertive and the switchover
wait time is 0 seconds.