  • Page 1: Installation Guide

    HPE FlexNetwork HSR6800 Routers Installation Guide Part number: 5998-7249s Document version: 6W104-20160520...
  • Page 2 © Copyright 2015, 2016 Hewlett Packard Enterprise Development LP The information contained herein is subject to change without notice. The only warranties for Hewlett Packard Enterprise products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. Hewlett Packard Enterprise shall not be liable for technical or editorial errors or omissions contained herein.
  • Page 3: Table Of Contents

    Contents Preparing for installation ················································································· 1 Safety recommendations ··································································································································· 1 Safety symbols ··········································································································································· 1 Electricity safety ········································································································································· 1 Laser safety ················································································································································ 1 Moving the router ······································································································································· 2 ESD prevention ·········································································································································· 2 Examining the installation site ···························································································································· 3 Weight support ··········································································································································· 3 Temperature and humidity ·························································································································...
  • Page 4 Accessing the router ····················································································· 31 Login methods ················································································································································· 31 Logging in through the console port ················································································································· 31 Setting up a configuration environment ···································································································· 31 Setting terminal parameters ····················································································································· 32 Powering on the router ····································································································································· 34 Verifying before power-on ························································································································ 34 Powering on the router ·····························································································································...
  • Page 5 Power LED is off ······································································································································ 60 Red power LED is on ······························································································································· 60 Fan failures ······················································································································································ 61 Fan tray is absent ····································································································································· 61 ALM LED is red ········································································································································ 61 HIM/MIM failures ·············································································································································· 61 Configuration system problems ······················································································································· 62 No terminal display ··································································································································· 62 Garbled terminal display ··························································································································...
  • Page 6 SAP-4EXP ·············································································································································· 108 SAP-20GE2XP ······································································································································· 109 SAP-28GE ·············································································································································· 113 SPE/OAP ······················································································································································· 116 HIM/MIM ························································································································································ 116 Appendix B LEDs ························································································ 117 MPU and switching fabric module LEDs ········································································································ 117 LPU LEDs ······················································································································································ 118 FIP LEDs ················································································································································ 118 SAP LEDs ·············································································································································· 122 SPE LEDs ······················································································································································...
  • Page 7: Preparing For Installation

    Preparing for installation Safety recommendations To avoid any equipment damage or bodily injury caused by improper use, read the following safety recommendations before installation. Note that the recommendations do not cover every possible hazardous condition. Safety symbols When reading this document, note the following symbols: WARNING means an alert that calls attention to important information that if not understood or followed can result in personal injury.
  • Page 8: Moving The Router

    • To pass a fiber through a metallic board hole, make sure the fiber has protective covering and the hole has a smooth and fully filleted surface. (The filleting radius must be not less than 2 mm, or 0.08 in.) •...
  • Page 9: Examining The Installation Site

    Insert the ESD plug into the ESD socket. Make sure the rack is reliably grounded. Figure 1 Attaching an ESD wrist strap (1) ESD wrist strap (2) Lock (3) ESD plug Examining the installation site The routers can only be used indoors. To make sure the router operates correctly and to prolong its service lifetime, the installation site must meet the following requirements.
  • Page 10: Altitude

    Table 1 Temperature requirements Item Temperature Operating temperature 0°C to 45°C (32°F to 113°F) Storage temperature –40°C to +70°C (–40°F to +158°F) Table 2 Humidity requirements Item Humidity Operating humidity (noncondensing) 10% RH to 95% RH Storage humidity (noncondensing) 5% RH to 95% RH Altitude Table 3 Altitude requirements Item...
  • Page 11: Cooling System

    Cooling system Fan trays are hot swappable and support automatic fan speed adjustment. To ensure good ventilation, the following requirements must be met: • Leave a minimum clearance of 10 cm (3.94 in) at the inlet and outlet air vents. •...
  • Page 12: Emi

    Figure 3 Airflow through the HSR6808 chassis All electromagnetic interference (EMI) sources, from outside or inside of the switch and application system, adversely affect the switch in the following ways: • A conduction pattern of capacitance coupling. • Inductance coupling. •...
  • Page 13: Space

    • Make sure the grounding terminal of the AC power receptacle is reliably grounded. • Install a lightning arrester at the input end of the power supply to enhance the lightning protection capability of the power supply. • Install a special lightning arrester at the input end of outdoor signal lines (for example, E1 line) to which interface modules of the router are connected to enhance the lightning protection capability.
  • Page 14 Product code Item Quantity • M6 cage nut: M6 screw and cage nut • HSR6802: 4 sets 5185-8965 • HSR6804:10 sets • M6 screw: • HSR6808:12 sets 5185-8966 Power supply blank panel • HSR6802: 1 • HSR6804: 1 5003-1616 • HSR6808: 3 Blank panel 5003-1604...
  • Page 15: Installing The Router

    Installing the router Installation workflow Figure 4 Installation workflow Installing a cable management bracket The cable management brackets of the HSR6802 and HSR6804 are provided with mounting brackets. You need to install a cable management bracket for an HSR6808 router. To install a cable management bracket: Face the front of the router.
  • Page 16: Installing The Router In A 19-Inch Rack

    Figure 5 Installing a cable management bracket Installing the router in a 19-inch rack The procedures for installing an HSR6800 router in a rack are similar. This section uses an HSR6802 router as an example. To install the router in a rack, you need mounting brackets and a rack shelf. Attaching cage nuts to the rack Locate the installation position for the router and then attach a rack shelf to the rack.
  • Page 17: Attaching The Mounting Brackets To The Router

    Figure 6 Marking the positions of cage nuts Insert one edge of a cage nut into the hole. Use a flat-blade screwdriver to compress the other edge of the cage nut, and then push the cage nut fully into the hole. Repeat steps 3 and 4 to install other cage nuts to all the marked positions on the rack post.
  • Page 18: Installing The Router In A 19-Inch Rack

    Figure 8 Attaching the front mounting brackets to the two sides of the router Installing the router in a 19-inch rack Put the router on the rack shelf. Slide the router into the rack so the screw holes on the mounting brackets are aligned with holes that are installed with cage nuts on the rack posts.
  • Page 19: Installing Power Supplies

    IMPORTANT: • The resistance reading should be smaller than 5 ohms between the chassis and the ground. • To guarantee the grounding effect, use the grounding cable provided with the router to connect to the grounding strip in the equipment room. To connect the grounding cable: Remove the two grounding screws from the grounding holes at the rear panel of the chassis.
  • Page 20: Installing Mpus And Switching Fabric Modules

    Figure 11 Installing a power supply Installing MPUs and switching fabric modules Installing an MPU CAUTION: The RUN LED flashes fast when the MPU is starting up. Do not install or remove the MPU during this period to avoid hardware damage. Before installing an MPU, pivot the ejector levers on the MPU outward.
  • Page 21: Installing Lpus

    Face the front of the router and locate the slot. Loosen the captive screws with a Phillips screwdriver to remove the filler panel from the slot. Keep the removed filler panel for future use. Insert the SFE-X1 slowly along the slide rails until positioning pins on the backplane are seated in the positioning holes, and then push the ejector levers inward to lock the SFE-X1 in position.
  • Page 22: Installing Hims/Mims

    Face the front of the router and locate the slot to be used. Loosen the captive screws with a Phillips screwdriver to remove the filler panel from the slot. Keep the removed filler panel for future use. Skip this step if you are installing the FIP-210 to Slot 3 of the HSR6802/HSR6804, or Slot 7 of the HSR6808.
  • Page 23: Installing A Cf Card

    Figure 15 Pushing the MIM into the slot Installing a CF card Push the CF card eject button all the way into the slot, and make sure the button does not project from the panel. Insert the CF card into the slot, as shown in Figure 16, and make sure it does not project from the slot.
  • Page 24 Figure 17 Installing the upper and lower slide rails Push the air filter along the slide rails from the rear side of the chassis to the front. Figure 18 Inserting the air filter to the slide rail Use a Phillips screwdriver to fasten the captive screws on the rear side of the air filter.
  • Page 25: Connecting Power Cords

    Figure 19 Fastening the captive screws Installing an air filter on an HSR6808 Face the front of the router. Align the positioning pins on the air filter with the screw holes on the inlet vent area, and use a Phillips screwdriver to fasten the screws on the air filter. Figure 20 Installing an air filter on an HSR6808 Connecting power cords Connecting an AC power cord...
  • Page 26: Connecting Dc Power Cords

    Figure 21 Connecting an AC power cord to the router Connecting DC power cords Connecting power cords for the PSR650-D WARNING! To avoid connection mistakes, identify the label on the DC power cord. CAUTION: The power cord color code scheme in Figure 22 is for illustration only.
  • Page 27 Figure 22 Connecting DC power cords Connecting power cords for the PSR1200-D CAUTION: The power cord color code scheme in this section is for illustration only. The cable delivered for your country or region might use a different color scheme. When you connect a power cord, always identify the polarity symbol on its wires.
  • Page 28 Figure 24 Attaching the power cords to the power supply connector Insert the power supply connector in right direction into the power supply, and fasten the captive screws with a Phillips screwdriver. Figure 25 Installing the power supply connector to the power supply Connect the other ends of the wires to the DC power source wiring terminals, with the negative wire (–...
  • Page 29: Connecting Interface Cables

    Connecting interface cables Connecting the AUX cable Overview An AUX cable has a crimped RJ-45 connector at one end for connecting to the AUX port of the router, and D9 male connectors at the other end for connecting to the serial port of the modem. Figure 26 AUX cable Connecting the AUX cable Plug the D9 male connector at one end of the AUX cable into the serial port of the modem.
  • Page 30: Connecting An Ethernet Cable

    Connecting an Ethernet cable Overview 10/100 Mbps Ethernet uses category-5 twisted pair cables, while 1000 Mbps Ethernet uses category-5 enhanced or category-6 twisted pair cables. Twisted pair cables include straight-through cables and crossover cables. Category-5 cables provide a transmission frequency of 100 MHz for voice and data transmission and they are typically used in 100Base-T and 10Base-T networks.
  • Page 31 Pin No. Wire color Orange solid White/Brown strip Brown Solid Table 8 T568A pinouts Pinout No. Wire color White/Orange strip Orange solid White/Green strip Blue solid White/Blue strip Green solid White/Brown strip Brown solid Ethernet twisted pair cables can be classified into straight-through and crossover cables based on their pinouts.
  • Page 32: Making An Ethernet Cable

    Pinout No. Brown solid Brown solid NOTE: To avoid affecting communication quality, follow the pinout descriptions in Table 9 Table 10 when identifying or making the two types of Ethernet cables. Making an Ethernet cable Cut the cable to the desired length with crimping pliers. Strip off an appropriate length of the cable sheath.
  • Page 33: Fiber Cable Overview

    Figure 30 XFP transceiver module Figure 31 SFP+ transceiver module Fiber cable overview CAUTION: • Never use excessive force when you insert or remove a fiber connector. • Never use excess force when you pull, press, or extrude the fiber. Optical fibers can be classified into single-mode optical fibers and multi-mode optical fibers.
  • Page 34: Connecting A Fiber Cable

    Table 12 Allowed maximum tensile force and crush load Period of force Tensile load (N) Crush load (N/mm) Short period Long term Fiber connectors are indispensable passive components in an optical fiber communication system. They allow the removable connection between optical channels, which makes the optical system debugging and maintenance more convenient.
  • Page 35: Connecting A T1 Cable

    Figure 33 Connecting a fiber cable Connecting a T1 cable Overview T1 cable CAUTION: • When connecting the interface cable, pay attention to the mark on the interface to avoid insertion mistake, which might damage the interface module or the router. •...
  • Page 36: Connecting A T1 Cable

    Connecting a T1 cable Connect the D68 connector of the 8-port T1 cable to the D68 interface on the interface module and fasten the bolts to fix the cable. The other end of the cable provides eight RJ-45 connectors. Connect them to the RJ-45 interface on the remote device as needed.
  • Page 37: Accessing The Router

    Accessing the router Login methods The following logins methods are available for you to use to log in to the router: • Logging in through the console port, which is the most typical way to log in to a router and also the prerequisite for configuring other login methods.
  • Page 38: Setting Terminal Parameters

    Setting terminal parameters Select Start > All Programs > Accessories > Communications > HyperTerminal. The Connection Description dialog box appears. Figure 37 Connection description Select the serial port to be used from the Connect using list, and click OK. Figure 38 Setting the serial port used by the HyperTerminal connection Set Bits per second to 9600, Data bits to 8, Parity to None, Stop bits to 1, and Flow control to None, and click OK.
  • Page 39 Figure 39 Setting the serial port parameters Select File > Properties in the HyperTerminal window. Figure 40 HyperTerminal window On the Settings tab, set the emulation to VT100 and click OK.
  • Page 40: Powering On The Router

    Figure 41 Setting terminal emulation in test Properties dialog box Powering on the router Verifying before power-on Before powering on the router, verify the following items: • The power supplies and fan trays are correctly installed. • The power cord and grounding cable are correctly connected. •...
  • Page 41 Press Ctrl+T to start memory test Booting Normal Extended BootWare The Extended BootWare is self-decompressing.......Done. **************************************************************************** HPE Router BootWare, Version 2.04 **************************************************************************** Copyright (c) 2010-2015 Hewlett Packard Enterprise Development LP Compiled Date : Nov 6 2015 CPU Type : P2020 CPU L1 Cache : 32KB CPU Clock Speed...
  • Page 42: Logging In To The Router Through Telnet/Ssh

    ................................Done. System image is starting... Line con1/1 is available. Press ENTER to get started. Press Enter, and the following prompt appears: <HPE> You can now configure the router. Logging in to the router through Telnet/SSH After powering on the router, log in to the router through the console port. Use the telnet server enable command and the ssh server enable command to enable the Telnet and SSH function on the router, respectively, and use the user privilege level command to set the user privilege level.
  • Page 43 Step Command Remarks Enter system view. Available in user view. system-view interface interface-type Enter Ethernet interface view. interface-number Specify an IP address for the By default, no IP address is ip address ip-address interface. { mask-length | mask } [ sub ] assigned to any interface.
  • Page 44: Replacement Procedures

    Replacement procedures All modules of the HPE HSR6800 routers are field replaceable. Safety recommendations Always wear an ESD wrist strap or ESD gloves when you replace the modules. All transceiver modules are hot swappable. If you need to replace LPUs or HIMs/MIMs when the router is powered on, first use the command remove slot slot-number to stop them from working.
  • Page 45: Replacing An Mpu And A Switching Fabric Module

    To replace the active MPU, execute the slave switchover command to trigger an active and standby switchover. For more information about the slave switchover command, see HPE FlexNetwork HSR6800 Routers High Availability Command Reference. To replace the standby MPU, remove it directly.
  • Page 46: Replacing An Lpu

    Figure 44 Pulling the SFE-X1 out of the slot (HSR6808) Install a new SFE-X1. For the installation procedure, see "Installing an SFE-X1 switching fabric module." If you do not install a new SFE-X1 in the slot, install a filler panel. Replacing an LPU CAUTION: To avoid hardware damage, do not replace the LPU when its RUN LED is fast flashing.
  • Page 47: Replacing A Him/Mim

    Figure 45 Pulling the FIP module out of the slot Install a new FIP module. For the installation procedure, see "Installing LPU." If you do not install a new FIP module in the slot, install a filler panel. Replacing a HIM/MIM The procedures for replacing HIMs and MIMs are similar.
  • Page 48: Replacing A Cf Card

    Replacing a CF card CAUTION: To avoid hardware damage, do not remove the CF card when the router is booting or the CF LED is flashing. To replace a CF card: Press the CF card eject button of the CF card reader so that the eject button projects from the panel.
  • Page 49: Replacing A Fan Tray

    Replacing a fan tray CAUTION: • Keep your hands away from the spinning fan blades when removing the fan tray. • Do not keep the router working without a fan tray for more than two minutes because poor ventilation might result in damage to the router. Replacing a fan tray for an HSR6802/HSR6804 router The methods for replacing fan trays for the HSR6802 and HSR6804 are the same.
  • Page 50: Replacing An Air Filter

    Figure 50 Pulling out the fan tray Replacing an air filter IMPORTANT: You can clean the air filter with water, but wait until it is completely dry before installing it again. Replacing an air filter for an HSR6802/HSR6804 router Face the left side of the router. Use a Phillips screwdriver to completely loosen the captive screws of the air filter.
  • Page 51: Replacing An Air Filter For An Hsr6808 Router

    Figure 52 Pulling the air filter out along the slide rails Install a new air filter. For the installation procedure, see "Installing an air filter on an HSR6802/HSR6804." Replacing an air filter for an HSR6808 router Face the front of the router. Use a Phillips screwdriver to completely loosen the captive screws of the air filter.
  • Page 52: Memory Module Structure

    Memory module structure Figure 54 Memory module structure (DDR2) (a) Front view (b) Rear view (1) Connector edge (2) Polarization notch (3) Latch notch Figure 55 Memory module structure (DDR3) (1) Connector edge (2) Polarization notch (3) Latch notch Replacing a memory module The methods for replacing memory modules are similar.
  • Page 53 Figure 56 Replacing a memory module...
  • Page 54: Hardware Management And Maintenance

    Hardware management and maintenance The output depends on your router model and software version. For more information about the commands used in this chapter, see HPE FlexNetwork HSR6800 Routers Command References. Displaying the hardware information of the router Displaying the version information of the router Use the display version command to display software and hardware version information of the router.
  • Page 55: Displaying Detailed Information About A Card

    Please input the file name(*.gz)[cfa0:/diag.gz]:aa.diag.gz Diagnostic information is outputting to cfa0:/aa.diag.gz. Please wait... Save successfully. Execute the more aa.diag command in user view, and then press the Page Up and Page Down keys to view the contents of the file aa.diag. •...
  • Page 56: Displaying The Electrical Label Data

    Chassis 1: Chassis self: DEVICE_NAME:HP HSR6802 Router Chassis JG361B DEVICE_SERIAL_NUMBER:CN5AGY3123 MAC_ADDRESS:NONE MANUFACTURING_DATE:2015-10-16 VENDOR_NAME:HPE Slot 1 CPU 0: DEVICE_NAME:HP HSR6800 RSE-X3 Router MPU JH075A DEVICE_SERIAL_NUMBER:CN59GXY123 MAC_ADDRESS:NONE MANUFACTURING_DATE:2015-9-15 VENDOR_NAME:HPE Slot 2 CPU 0: DEVICE_NAME:HP HSR6800 FIP-600 FlexIntfPltfm Rtr Mod JG360A DEVICE_SERIAL_NUMBER:CN59FS3123 MAC_ADDRESS:NONE MANUFACTURING_DATE:2015-9-15...
  • Page 57: Displaying The Cpu Usage Statistics

    VENDOR_NAME:HPE Slot 3 CPU 0: DEVICE_NAME:HP HSR6800 FIP-600 FlexIntfPltfm Rtr Mod JG360A DEVICE_SERIAL_NUMBER:CN59FS3123 MAC_ADDRESS:NONE MANUFACTURING_DATE:2015-9-15 VENDOR_NAME:HPE Fan 1: DEVICE_NAME:HP HSR6802 Router Spare Fan Assembly JG367A DEVICE_SERIAL_NUMBER:CN5BFSB123 MAC_ADDRESS:NONE MANUFACTURING_DATE:2015-10-16 VENDOR_NAME:HPE • Use the display device manuinfo slot slot-number command to display the electrical label data for the card in the specified slot.
  • Page 58: Displaying The Mpu Memory Usage

    Table 15 Command output Field Description CPU usage of the card in slot 0. If the card in the slot has multiple CPUs: • Slot 0 CPU usage displays the usage of the master CPU of the card Slot 0 CPU usage in slot 0.
  • Page 59: Displaying The Fan Operating Status

    Table 17 Command output Field Description Slot No. Slot number of the CF card. Device number of the CF card: • Dev No. 0 for a built-in CF card. • 1 for an external CF card. Operating status of the CF card: •...
  • Page 60: Displaying The Alarming Thresholds Of A Card

    Displaying the alarming thresholds of a card Use the display environment command to display the temperature information and alarming thresholds of a card. <Sysname> display environment System temperature information (degree centigrade): ------------------------------------------------------------------------------ Slot Sensor Temperature LowerLimit WarningLimit AlarmLimit ShutdownLimit 1/Vent Hotspot 1 25 Outflow 1 29 Hotspot 1 34 Table 20 Command output...
  • Page 61: Displaying And Verifying Transceiver Modules

    GigabitEthernet5/0/1 Current state: DOWN Line protocol state: DOWN Description: GigabitEthernet5/0/1 Interface Bandwidth: 1000000kbps Maximum Transmit Unit: 1500 Internet protocol processing : disabled IP Packet Frame Type: PKTFMT_ETHNT_2, Hardware Address: 2222-2222-2122 IPv6 Packet Frame Type: PKTFMT_ETHNT_2, Hardware Address: 2222-2222-2122 Media type is optical fiber, loopback not set, promiscuous mode not set …...
  • Page 62: Rebooting A Card Or Router

    Whether can be Whether can be Application Transceiver module type an optical an copper scenarios transceiver transceiver SFP+ (enhanced small Generally used for 10G Yes. form-factor pluggable) interfaces. Displaying transceiver module information Task Command Remarks Available for all transceiver modules. You can use the display transceiver interface command to view the key parameters of the...
  • Page 63 • Power cycle the router. This method might cause data loss, and is the least-preferred method. The first and second methods are called warm reboot or warm startup, and can be used remotely. The third method is called cold reboot or cold startup. For data security, if you reboot the router while the router is performing file operations, the router does not reboot.
  • Page 64: Troubleshooting

    Troubleshooting IMPORTANT: The barcode on the router chassis contains production and servicing information. Before you return a faulty router for serving, provide the barcode information of the router to Hewlett Packard Enterprise Support. MPU failures RUN LED is off Symptom The RUN LED for the MPU is off.
  • Page 65: Palm Led Is Steady On

    PALM LED is steady on Symptom The PALM LED for the MPU is steady on. For more information about MPU LEDs, see Table Solution To resolve the problem: Verify that the power supply and power consumption match. For example, if an HSR6808 is installed with a 650 W power supply but two SAP-48GBE modules, the power available is not sufficient for the whole power consumption and one SAP module cannot be powered on.
  • Page 66: Run Led Fast Flashes

    %Apr 26 16:46:32:169 2012 HPE DRVMSG/1/InSufficientPwr: No sufficient power, failed to power on slot 3. Execute the display version command to verify that the LPU is in position: Slot3: The Board is present, state is unknown If the problem persists, contact Hewlett Packard Enterprise Support. RUN LED fast flashes Symptom 20 minutes after the router is powered on or the LPU is inserted into the router, the RUN LED for the...
  • Page 67: Fan Failures

    Turn off the power switch, and verify that the power supply is firmly seated. Verify that the power source meets the requirements of the router. If the problem persists, contact Hewlett Packard Enterprise Support. Fan failures Fan tray is absent Symptom After the router is booted, the output from the configuration terminal shows that the fan tray is not in position.
  • Page 68: Configuration System Problems

    Solution To resolve the problem: Verify that the HIM/MIM is firmly seated. Verify that the HIM/MIM is correctly inserted into a FIP module. Verify that the HIM/MIM connector pins of the FIP module are not bent. If the problem persists, contact Hewlett Packard Enterprise Support. Configuration system problems If the configuration environment setup is correct, the configuration terminal displays boot information when the router is powered on.
  • Page 69: No Response From The Serial Port

    No response from the serial port Symptom The serial port gives no response. Solution To resolve the problem: Verify that the serial port settings are correct. If the problem persists, contact Hewlett Packard Enterprise Support. For more information about the serial port settings, see "Configuring basic settings."...
  • Page 70: Examining The State Of Password Recovery Capability

    Examining the state of password recovery capability Reboot the router. System is starting... Press Ctrl+D to access BASIC-BOOTWARE MENU Press Ctrl+T to start memory test Booting Normal Extended BootWare The Extended BootWare is self-decompressing.......Done. **************************************************************************** HPE Router BootWare, Version 2.04 **************************************************************************** Copyright (c) 2010-2015 Hewlett Packard Enterprise Development LP Compiled Date...
  • Page 71: Console Login Password Loss When Password Recovery Capability Is Enabled

    |<9> Storage Device Operation |<0> Reboot ============================================================================ Ctrl+Z: Access EXTENDED ASSISTANT MENU Ctrl+F: Format File System Ctrl+C: Display Copyright Enter your choice(0-9): Console login password loss when password recovery capability is enabled Reboot the router to access the EXTEND-BOOTWARE menu, and then enter 6. Password recovery capability is enabled.
  • Page 72: User Privilege Level Password Loss When Password Recovery Capability Is Enabled

    [HPE] user-interface console 0 [HPE-ui-console0] authentication-mode password [HPE-ui-console0] set authentication password cipher 123456 To make the settings take effect after a reboot, save the running configuration to the next-startup configuration file. [HPE] save User privilege level password loss when password recovery capability is enabled Reboot the router to access the EXTEND-BOOTWARE menu, and then enter 8.
  • Page 73: Password Loss When Password Recovery Capability Is Disabled

    Password loss when password recovery capability is disabled Reboot the router to access the EXTEND-BOOTWARE menu, and enter 5. Password recovery capability is enabled. Note: The current operating device is cfa0 Enter < Storage Device Operation > to select device. ==========================<EXTENDED-BOOTWARE MENU>========================== |<1>...
  • Page 74: Ethernet Port Failure

    %Jun 14 11:54:38:179 2012 HPE DEVM/4/BOARD_TEMP_TOOHIGH: Board temperature is to o high on Chassis 0 Slot 1, type is RSE-X2. The output shows that the temperature inside the router has exceeded the upper threshold. In this case, the fans of the router will rotate at full speed. Typically, after the fans rotate at full speed for a certain period, the temperature inside the router will drop below the upper threshold, and the following information appears on the configuration terminal: #Jun 14 11:56:48:279 2012 HPE DEVM/1/BOARD TEMPERATURE UPPER:...
  • Page 75: Him/Mim, Cable, And Connection Failure

    HIM/MIM, cable, and connection failure Symptom Power on the router after a HIM/MIM is installed. The LEDs on the HIM/MIM panel indicate abnormal operation. Solution To resolve the problem: Verify that the HIM/MIM cable is correctly selected. Verify that the HIM/MIM cable is correctly connected. Use the display command to verify that the interface of the HIM/MIM has been correctly configured and is operating correctly.
  • Page 76: Ftp Upgrade Failure

    Type the correct file name. Configure the network port correctly, and make sure the network port is up and you can successfully ping the TFTP server from the network port. If the problem persists, contact Hewlett Packard Enterprise Support. FTP upgrade failure Symptom Start the router, and upgrade the software through FTP.
  • Page 77 Solution To solve this problem: Either download the application package again or set the file attributes in the BootWare file list. If the problem persists, contact Hewlett Packard Enterprise Support.
  • Page 78: Document Conventions And Icons

    Document conventions and icons Conventions This section describes the conventions used in the documentation. Port numbering in examples The port numbers in this document are for illustration only and might be unavailable on your device. Command conventions Convention Description Bold text represents commands and keywords that you enter literally as shown. Boldface Italic text represents arguments that you replace with actual values.
  • Page 79: Network Topology Icons

    Network topology icons Convention Description Represents a generic network device, such as a router, switch, or firewall. Represents a routing-capable device, such as a router or Layer 3 switch. Represents a generic switch, such as a Layer 2 or Layer 3 switch, or a router that supports Layer 2 forwarding and other Layer 2 features.
  • Page 80: Support And Other Resources

    Hewlett Packard Enterprise Support Center More Information on Access to Support Materials page: www.hpe.com/support/AccessToSupportMaterials IMPORTANT: Access to some updates might require product entitlement when accessed through the Hewlett Packard Enterprise Support Center. You must have an HP Passport set up with relevant entitlements.
  • Page 81: Websites

    Websites Website Link Networking websites Hewlett Packard Enterprise Information Library for www.hpe.com/networking/resourcefinder Networking Hewlett Packard Enterprise Networking website www.hpe.com/info/networking Hewlett Packard Enterprise My Networking website www.hpe.com/networking/support Hewlett Packard Enterprise My Networking Portal www.hpe.com/networking/mynetworking Hewlett Packard Enterprise Networking Warranty www.hpe.com/networking/warranty General websites Hewlett Packard Enterprise Information Library www.hpe.com/info/enterprise/docs Hewlett Packard Enterprise Support Center...
  • Page 82 part number, edition, and publication date located on the front cover of the document. For online help content, include the product name, product version, help edition, and publication date located on the legal notices page.
  • Page 83: Appendix A Chassis Views And Technical Specifications

    JG363B BJNGA-BB0004 HSR6808 Router chassis Table 24 MPU models Product code Description Alias HPE FlexNetwork HSR6800 RSE-X2 Router Main Processing JG364A RSE-X2 Unit HPE FlexNetwork HSR6800 RSE-X2 Router TAA-compliant JG779A RSE-X2-TAA Main Processing Unit HPE FlexNetwork HSR6800 RSE-X3 Router Main Processing...
  • Page 84: Chassis Views

    SAP-24GBP Aggregation Platform Module HPE FlexNetwork 6600 48-port GbE SFP Service JG556A SAP-48GBP Aggregation Platform Module HPE FlexNetwork HSR6800 4-port 10GbE SFP+ Service JG366A SAP-4EXP Aggregation Platform Router Module HPE FlexNetwork 6600 16-port GbE SFP 4-port GbE JH139A Combo and 2-port 10GbE SFP+Service Aggregation...
  • Page 85: Hsr6802

    HSR6802 Figure 58 HSR6802 front view (1) MPU slots (Slot 0 and Slot 1) (2) Fan tray (3) Power supply slots (4) Line processing unit (LPU) slots (Slot 2 and Slot 3) Figure 59 HSR6802 rear view (1) Rear cover handle (2) Chassis handle (3) Grounding screw and sign (4) Air vents...
  • Page 86: Hsr6804

    HSR6804 Figure 60 HSR6804 front view (1) MPU slots (Slot 0 and Slot 1) (2) Fan tray (3) Power supply slots (4) LPU slots (Slot 2 to Slot 5) Figure 61 HSR6804 rear view (1) Rear cover handle (2) Chassis handle (3) Grounding screw and sign (4) Air vents...
  • Page 87: Hsr6808

    HSR6808 Figure 62 HSR6808 front view (1) Fan tray (2) Cable management bracket (3) LPU slots (Slot 0 to Slot 3 and Slot 7 to Slot 9) (4) MPU slots (Slot 4 and Slot 5) (5) Switching fabric module or LPU slot (Slot 6) (6) Air inlet vents (An optional air filter can be installed.) (7) Power supply slots...
  • Page 88: Dimensions And Weight

    Figure 63 HSR6808 rear view (1) Chassis air exhaust vents (2) Chassis handle (3) Rear cover handle (4) Grounding screw and sign (5) Power supply air exhaust vents Dimensions and weight Table 29 Router dimensions and weight Item HSR6802 HSR6804 HSR6808 308 mm (12.13 in) (7 886 mm (34.88 in) (20...
  • Page 89: Power Consumption

    Model Net weight Dimensions (H × W × D) SFE-X1 3.25 kg (7.16 lb) 45 × 399 × 412 mm (1.77 × 15.71 × 16.22 in) FIP-110 3.25 kg (7.16 lb) 45 × 399 × 412 mm (1.77 × 15.71 × 16.22 in) FIP-210 3.35 kg (7.39 lb) 45 ×...
  • Page 90: Power Supplies

    NOTE: The theoretical power consumption, which is greater than the actual power consumption, is the upper power consumption threshold defined to avoid power supply overloading. You must use the theoretical power consumption, rather than the actual power consumption, to calculate the total power consumption for managing power supplies and determining power supply numbers.
  • Page 91: Dc Power Supply

    PSR1200-A Figure 65 PSR1200-A view (1) AC-input power receptacle (2) Power switch (3) Handle (4) Power supply status LED Table 34 PSR1200-A specifications Item Remarks Rated input voltage 100 VAC to 240 VAC @ 50 or 60 Hz Maximum input current 16 A Maximum power 1213 W...
  • Page 92 Table 35 PSR650-D specifications Item Remarks Rated input voltage –48 VDC to –60 VDC Maximum input current 25 A Maximum power 650 W PSR1200-D Figure 67 PSR1200-D view (1) Power supply connector (2) Power switch (3) Handle (4) Power supply status LED Table 36 PSR1200-D specifications Item Remarks...
  • Page 93: Fan Tray Specifications

    Fan tray specifications Figure 68 Fan tray for the HSR6802 Figure 69 Fan tray for the HSR6804 (1) Fan (2) Fan tray status LED (RUN) (3) Alarm LED (ALM) (4) Handle (5) Rotating blade hazard label...
  • Page 94: Mpu

    NOTE: The fan tray structure of the HSR6802 is similar to the HSR6804. Figure 70 Fan tray for the HSR6808 (1) Fan (2) Alarm LED (ALM) (3) Fan tray status LED (RUN) (4) Fan tray release button (5) Rotating blade hazard label Table 37 Fan tray specifications Fan tray HSR6802...
  • Page 95 RSE-X2 front panel Figure 71 RSE-X2 front panel (1) Management Ethernet port (MANAGEMENT) (2) AUX port (AUX) (3) MPU status LEDs (4) Reset button (RESET) (5) USB port (6) Console port (CONSOLE) (7) CF card slot (8) CF card button (9) CF card status LED RSE-X2 specifications Item...
  • Page 96: Components

    Components CF card IMPORTANT: Use CF cards provided by Hewlett Packard Enterprise only. The router might be incompatible with other CF cards. A compact flash (CF) card stores logs, system software image files, and configuration files. The router is equipped with a built-in CF card, which is identified with cfa0. In addition, the router provides an external CF card slot to expand the storage space.
  • Page 97 NOTE: The dialup function for an AUX port is supported only on Comware V5. For MPU and Comware compatibility, see "MPU and Comware compatibility matrix." Management Ethernet port The management Ethernet port is a 10Base-T/100Base-TX/1000Base-T autosensing RJ-45 port. It allows you to upgrade software and manage the router through a network management server without using any service interface of the router.
  • Page 98: Switching Fabric Modules

    Switching fabric modules SFE-X1 The SFE-X1 includes a built-in 1024-Gbps switch fabric and is designed for the HSR6808 by Hewlett Packard Enterprise to improve the router's switching capability. NOTE: Only the HSR6808 routers support SFE-X1. SFE-X1 front panel Figure 72 SFE-X1 front panel (1) Captive screw (2) Ejector lever (3) Switching fabric module status LED (RUN)
  • Page 99: Lpu

    To switch between the copper and fiber ports, use the combo enable { copper | fiber } command in interface view. For more information about the combo enable { copper | fiber } command, see HPE FlexNetwork HSR6800 Routers Interface Command Reference.
  • Page 100 FIP-110 combo interface specifications Table 42 FIP-110 copper Ethernet port specifications Item Remarks Connector RJ-45 Interface type Autosensing Ethernet_II Supported frame format Ethernet_SNAP 10 Mbps Half/full duplex, auto-negotiation Interface speed and 100 Mbps Half/full duplex, auto-negotiation duplex mode 1000 Mbps Full duplex, auto-negotiation Table 43 FIP-110 fiber Ethernet port specifications Item...
  • Page 101: Fip-210

    Max. Product Central Description Connector Optical fiber transmission code wavelength distance SFP LC LH100 single-mode (62.14 miles) Transceiver optical fiber NOTE: The BIDI modules must be used in pairs. For example, if you install JD098B in the local port, you must install JD099B in the peer port.
  • Page 102: Fip-240

    To switch between the copper and fiber ports, use the combo enable { copper | fiber } command in interface view. For more information about the combo enable { copper | fiber } command, see HPE FlexNetwork HSR6800 Routers Interface Command Reference.
  • Page 103: Fip-300

    To switch between the copper and fiber ports, use the combo enable { copper | fiber } command in interface view. For more information about the combo enable { copper | fiber } command, see HPE FlexNetwork HSR6800 Routers Interface Command Reference.
  • Page 104 To switch between the copper and fiber ports, use the combo enable { copper | fiber } command in interface view. For more information about the combo enable { copper | fiber } command, see HPE FlexNetwork HSR6800 Routers Interface Command Reference.
  • Page 105: Fip-310

    Max. Product Central Description Connector Optical fiber transmission code wavelength distance Transceiver pair cables HPE X120 9/125 µm 10 km 100M/1G SFP JF832A 1310 nm single-mode LC LX (6.21 miles) optical fiber Transceiver HPE X120 1G 62.5/125 µm 0.55 km JD118B SFP LC SX 850 nm...
  • Page 106 To switch between the copper and fiber ports, use the combo enable { copper | fiber } command in interface view. For more information about the combo enable { copper | fiber } command, see HPE FlexNetwork HSR6800 Routers Interface Command Reference.
  • Page 107 Table 46 Transceiver modules available for the SFP ports Max. Product Central Description Connector Optical fiber transmission code wavelength distance HPE X120 1G Category 5 or JD089B SFP RJ45 T RJ-45 above twisted pair 100 m (328.08 ft) Transceiver cables HPE X120 9/125 µm 10 km...
  • Page 108 Table 48 Transceiver modules for the SFP+ port Product Central Fiber Description Connector transmission code wavelength specifications distance HPE X130 10G SFP+ LC 50/125 µm, JD092B 850 nm 300 m (984.25 ft) multi-mode Transceiver • 50/125 µm, HPE X130 multi-mode 10G SFP+ LC JD093B 1310 nm...
  • Page 109: 103

    To switch between the copper and fiber ports, use the combo enable { copper | fiber } command in interface view. For more information about the combo enable { copper | fiber } command, see HPE FlexNetwork HSR6800 Routers Interface Command Reference.
  • Page 110: Sap-48Gbe

    Transceiver modules for the FIP-600 and for the FIP-110 fiber ports are the same. For more information, see Table Maximum interface modules provided by FIP-600 in full configuration FIP/Interface HSR6802 HSR6804 HSR6808 module FIP-600 Not supported Not supported Not supported SAP-48GBE SAP-48GBE front panel Figure 79 SAP-48GBE front panel...
  • Page 111: Sap-24Gbp

    SAP-24GBP CAUTION: Use transceiver modules provided by Hewlett Packard Enterprise only. The router might be incompatible with transceiver modules from other vendors. The system generates an alarm when a transceiver module from another vendor is installed. SAP-24GBP front panel Figure 80 SAP-24GBP front panel (1) SFP ports 0 to 23 (2) SAP module status LED (RUN) (3) LEDs for SFP ports 0 to 23...
  • Page 112 Table 51 Transceiver modules available for the SAP-24GBP fiber ports Max. Product Central Description Connector Optical fiber transmission code wavelength distance HPE X120 1G Category 5 or above 100 m (328.08 JD089B SFP RJ45 T RJ-45 twisted pair cables Transceiver HPE X110 62.5/125 µm 100M SFP LC...
  • Page 113: Sap-48Gbp

    Max. Product Central Description Connector Optical fiber transmission code wavelength distance SFP LC LH40 optical fiber (24.86 miles) 1550nm Transceiver HPE X120 1G 100 km 9/125 µm single-mode JD103A SFP LC LH100 1550 nm optical fiber (62.14 miles) Transceiver NOTE: The BIDI modules must be used in pairs.
  • Page 114: Sap-4Exp

    Item Remarks Hot swapping Supported SAP-48GBP fixed Ethernet port specifications The fixed Ethernet ports of the SAP-48GBP have the same specifications as the fiber ports of the FIP-110 combo interfaces. For more information, see Table Transceiver modules for the SAP-48GBP and the SAP-24GBP fiber ports are the same. For more information, see Table SAP-4EXP...
  • Page 115: Sap-20Ge2Xp

    Table 53 Transceiver modules available for the SAP-4EXP 10G Ethernet ports Product Central Description Connector Optical fiber transmission code wavelength distance HPE X130 10G SFP+ LC 50/125 µm, JD092B 850 nm 300 m (984.25 ft) multi-mode Transceiver HPE X130 10G SFP+ LC 9/125 µm, single JD094B 1310 nm...
  • Page 116 Item Specification 16 × SFP ports, 100/1000 Mbps auto-sensing. The following transceiver modules are available for the SFP ports: • 100 Mbps SFP transceiver modules. SFP ports • 1000 Mbps SFP transceiver modules. • 100/1000 Mbps SFP transceiver modules. • 10/100/1000 Mbps SFP copper transceiver modules supporting fiber-to-copper conversion.
  • Page 117 Product Central Description Connector Optical fiber transmission code wavelength distance Transceiver • Tx: 1310 HPE X115 100M 9/125 µm 15 km JD100A SFP LC BX 10-U single-mode • Rx: 1550 (9.32 miles) Transceiver optical fiber • Tx: 1550 HPE X115 100M 9/125 µm 15 km JD101A...
  • Page 118 Item Specification • Ethernet_SNAP 10 Mbps auto-sensing Half/full duplex, auto-negotiation Interface speed and duplex 100 Mbps auto-sensing Half/full duplex, auto-negotiation mode 1000 Mbps auto-sensing Full duplex, auto-negotiation For the combo fiber port specifications, see Table 54. For the transceiver module available for the combo fiber ports, see Table Table 57 SFP+ port specifications...
  • Page 119: Sap-28Ge

    Product Description Length Data rate Remarks code SFP+ SFP+ connecting SFP+ 0.65m DA Cable ports HPE X240 10G JD096C SFP+ SFP+ 1.2m 1.2 m (3.94 ft) DA Cable HPE X240 10G SFP+ SFP+ 3m JD097C 3 m (9.84 ft) DA Cable HPE X240 SFP+ JG081C SFP+ 5m DAC...
  • Page 120 Item Specification fiber-to-copper conversion. • Copper port—Straight-through/crossover autosensing: Combo interfaces 10/100 Mbps, half/full-duplex. 1000 Mbps, full-duplex. • Fiber port—1000 Mbps, full-duplex. Hot swapping Supported. SAP-28GE fixed Ethernet port specifications Table 60 SFP port specifications Item Specification Connector type Transceiver module type Network Supported...
  • Page 121 Product Central Description Connector Optical fiber transmission code wavelength distance HPE X120 9/125 µm 10 km JF832A 100M/1G SFP LC 1310 nm single-mode (6.21 miles) LX Transceiver optical fiber HPE X120 1G 62.5/125 µm, JD118B SFP LC SX 850 nm 0.55 km (0.34 miles) multi-mode Transceiver...
  • Page 122: Spe/Oap

    NOTE: Use transceiver modules for the fiber ports provided by Hewlett Packard Enterprise only. The router might be incompatible with transceiver modules from other vendors. The system generates an alarm when a transceiver module from another vendor is installed. SPE/OAP HPE HSR6800 routers support the service processing engine (SPE).
  • Page 123: Appendix B Leds

    Appendix B LEDs HPE HSR6800 routers provide LEDs for FRUs to indicate their operating status. MPU and switching fabric module LEDs The LEDs for the RSE-X2 and RSE-X3 are the same. Figure 85 uses the RSE-X2 as an example. Figure 85 RSE-X2 LEDs Table 63 RSE-X2 LED description Status Description...
  • Page 124: Lpu Leds

    Status Description No power input is available, or the MPU has failed. Slow flashing (1 The MPU is operating correctly. The system software is being loaded. (green) Fast flashing (8 CAUTION: To avoid hardware damage, do not power off the router or insert or remove the MPU.
  • Page 125 Figure 88 FIP-210 status LED Figure 89 FIP-240 status LED Figure 90 FIP-600 status LED Table 65 FIP-110/FIP-210/FIP-240/FIP-600 LED description Status Description No link is present. Steady green A 1000 Mbps link is present. Status LEDs Data is being received or transmitted at 1000 Flashing green for GE 0 to GE Mbps.
  • Page 126 Status Description (green) System software is being loaded. Fast flashing (8 CAUTION: To avoid hardware damage, do not power off the router, or insert or remove the FIP. No link is present. Steady green A link is present. Status LEDs for SFP 0 to Flashing green Data is being sent or received at 1000 Mbps.
  • Page 127 FIP-310 LEDs Figure 92 FIP-310 status LED Table 67 FIP-310 LED description Status Description No link is present. Steady green A 1000 Mbps link is present. Status LEDs Data is being received or transmitted at 1000 Flashing green for GE 0 to GE Mbps.
  • Page 128: Sap Leds

    SAP LEDs Figure 93 SAP-48GBE LEDs Table 68 SAP-48GBE LED description Status Description No link is present. Steady green A 1000 Mbps link is present. Status LEDs Flashing green Data is being received or transmitted at 1000 Mbps. for GE 0 to GE 47 (yellow/gree Steady yellow...
  • Page 129 Table 69 SAP-24GBP LED description Status Description No power input is available or the SAP-24GBP has failed. Slow flashing (1 The SAP-24GBP is operating correctly. System software is being loaded or the SAP-24GBP is not operating. (green) Fast flashing (8 CAUTION: To avoid hardware damage, do not power off the router, or insert or remove the SAP-24GBP when...
  • Page 130 Figure 96 SAP-4EXP LEDs Table 71 SAP-4EXP LED description Status Description No power input is available or the SAP-4EXP has failed. Slow flashing (1 Hz) The SAP-4EXP is operating correctly. System software is being loaded or the SAP-4EXP is not operating. (green) CAUTION: Fast flashing (8 Hz)
  • Page 131 Status Description SFP+ port Steady yellow The transceiver module has failed to be detected. No link is present. Status Steady green A 1000 Mbps link is present. LEDs for combo Data is being received or transmitted at 1000 Flashing green fiber ports Mbps.
  • Page 132: Spe Leds

    Status Description combo (yellow/green) Data is being received or transmitted at 1000 Flashing green fiber ports Mbps. GE16 to GE27 Steady yellow A 100 Mbps link is present. Flashing yellow Data is being received or transmitted at 100 Mbps. No link is present. Steady green A 1000 Mbps link is present.
  • Page 133 Figure 100 PSR1200-A AC power supply LED Figure 101 PSR650-D DC power supply LED Figure 102 PSR1200-D DC power supply LED Table 74 AC/DC power LED description Status Description Steady green The power supply is operating correctly. Power LED Steady red The power supply is faulty.
  • Page 134: Fan Leds

    Fan LEDs Figure 103 Fan LEDs for the HSR6802 Figure 104 Fan LEDs for the HSR6804...
  • Page 135 Figure 105 Fan LEDs for the HSR6808 Table 75 Fan LED description Status Description The system is powered off or the fan tray is faulty. Steady on The fan is operating correctly. (green) The fan is operating correctly. Steady on The fan is faulty.
  • Page 136: Appendix C Arranging Slots And Numbering Interfaces

    Appendix C Arranging slots and numbering interfaces Slot arrangement The router provides many types of interfaces, such as console, AUX, GigabitEthernet, POS, and E1 ports. This chapter describes how these interfaces are numbered. Figure 106 Slot arrangement on the HSR6802 Figure 107 Slot arrangement on the HSR6804...
  • Page 137: Available Slots For Cards

    Figure 108 Slot arrangement on the HSR6808 NOTE: Figure 106 through Figure 108, the blue and dark numbers represent slot numbers of the cards and power supplies, respectively. Available slots for cards Card HSR6802 HSR6804 HSR6808 RSE-X2/RSE-X3 (supporting 1+1 Slot 0 and Slot 1 Slot 0 and Slot 1 Slot 4 and Slot 5 redundancy)
  • Page 138: Numbering Interfaces

    Numbering interfaces Before installing a HIM/MIM, you must install a FIP. The interfaces of the router are numbered in the form of interface-type X/Y/Z: • interface-type—Type of the interface such as GE port. • X—Number of the slot where the FIP/SAP resides (for example, blue numbers in Figure 106 through Figure...
  • Page 139: Appendix D Cable Management

    Appendix D Cable management When you mount the router in a standard 19-inch rack, follow these guidelines to route the cables: • Bundle the network cables on the cable management brackets on the two sides of the rack and route the cables up or down along the rack based on the equipment room conditions. •...
  • Page 140 • Bind and route the cables neatly inside the rack, and make sure the cables are not kinked or bent. Figure 109 Correct and incorrect cable binding • Route different types of cables (for example, power cables, and signal cables) separately. If they are close to one another, cross them over one another.
  • Page 141 Figure 111 Binding the cables • Route, bind, and attach excess cables for easy, safe maintenance activities and correct operations. • Do not tie the power cables to the slide rails. • When you connect a cable to an articulated part, for example, when you connect a grounding cable to a cabinet door, leave enough slack in cables and make sure they are not stressed from any movement of the part.
  • Page 142: Cable Routing Example

    • Do not tie cables or bundles in a knot. • The metal parts of the crimped cold-pressed terminal blocks (such as circuit breaker) cannot protrude beyond the blocks. Cable routing example Cables on the router can be routed as shown in Figure 113.
  • Page 143: Appendix E Hardware Compatibility Matrixes

    Appendix E Hardware compatibility matrixes In the compatibility matrixes, "√" means "Supported" and "×" means "Not supported." MPU and Comware compatibility matrix Table 77 MPU and Comware compatibility matrix Comware V5 Comware V7 RSE-X2 √ × RSE-X3 × √ LPU and Comware compatibility matrix Table 78 LPU and Comware compatibility matrix Comware V5 Comware V7...
  • Page 144: Interface Module And Comware Compatibility Matrix

    Interface module and Comware compatibility matrix Table 79 Interface module and Comware compatibility matrix Interface module Comware V5 Comware V7 MIMs MIM-2GBE √ √ MIM-8T1 √ √ MIM-8T1-F √ √ HIMs HIM-8FE √ √ HIM-4GBE √ √ HIM-8GBE √ √ HIM-4GBP √...
  • Page 145: Index

    Index A C D E F G H I L M N P R S Installing a CF card,17 Installing HIMs/MIMs,16 Accessing updates,74 Installing LPUs,15 Available slots for cards,131 Installing MPUs and switching fabric modules,14 Installing optional components,17 Installing power supplies,13 Cable management guidelines,133...
  • Page 146 Replacing a transceiver module,42 Software upgrade failures,69 Replacing an air filter,44 LEDs,126 Replacing an LPU,40 SPE/OAP,116 Replacing an MPU and a switching fabric module,39 Switching fabric modules,92 System software image file missing errors,70 Slot arrangement,130...

Table of Contents