19.4. Disabling and Enabling Siren if Wireless Signal is lost
If a wireless device loses its wireless signal for 4-hour (by default) or longer, the system will send notification by SMS text message to user
phone number and activate the siren/bell. By default, the siren will not be activated when wireless signal is lost. to enable/disable this
feature, please refer to the following configuration methods.
Enable Siren if
Wireless Signal is lost
Disable Siren if
Wireless Signal is lost
19.5. EKB3W/EWKB4 - Wireless lED Keypad
Main features:
•
Alarm system arming and disarming (see 12.5. EKB3W/EWKB4 Keypad and User/Master Code).
Arming and disarming in Stay mode (see 15. StaY MoDE).
•
•
System parameter configuration (see 5. ConfIGUratIon MEtHoDS).
•
PGM output control (see 18.4. turning PGM outputs on and off).
•
Visual indication by LeD indicators (see 19.5.1. lED functionality).
•
Audio indication by built-in buzzer.
•
Keypad partition switch (see 23.3. Keypad Partition and Keypad Partition Switch).
For more details on technical specifications and installation, please refer to the latest user manual of the device located at
www.eldesalarms.com
19.5.1. lED functionality
IndIcatIon
steady on
system armed / exit delay in progress
(red)
Flashing
configuration mode activated
steady on
system is ready – no violated zones and/or violated tampers exist
(green)
steady on
system faults exist
(orange)
Flashing
Violated high-numbered zone
steady on
Violated zone bypassed
(orange)
1-12
steady on
Zone violated / configuration command being typed in
(red)
ESIM384 Installation and Configuration Manual v1.1
Menu path:
EKB2
OK → iiii → OK → PRIMARY SettINGS → OK → SIReN SettINGS →OK → SRN IF WLeSS LOSS
→ OK → eNABLe → OK
Value: iiii – 4-digit installer code.
Enter parameter 76 and parameter status value:
EKB3/
76 1 #
EKB3W/
EWKB4
Example: 761#
ElDES
Config-
this operation may be carried out from the PC using the ELDES Configuration software.
uration
software
Menu path:
EKB2
OK → iiii → OK → PRIMARY SettINGS → OK → SIReN SettINGS →OK → SRN IF WLeSS LOSS
→ OK → DISABLe → OK
Value: iiii – 4-digit installer code.
Enter parameter 76 and parameter status value:
EKB3/
76 0 #
EKB3W/
EWKB4
Example: 760#
ElDES
Config-
this operation may be carried out from the PC using the ELDES Configuration software.
uration
software
descrIptIon