13. EXIt anD EntrY DElaY

When arming, the system initiates the exit delay countdown (by default – 15 seconds) intended for the user to leave the secured area. the
exit delay is indicated by short beeps emitted by eKB2/eKB3/eKB3W/eWKB4 keypad buzzer and buzzer, connected to the alarm system.
When arming:
a non-partitioned system, a countdown timer will be displayed in the home screen view of eKB2 during exit delay.
a partitioned system, eKB2 keypad will display arMInG part-name message on the screen for 2 seconds and switch to partition
selection menu during exit delay.
exit delay is provided when arming the system by the following methods:
eKB2/eKB3/eKB3W/eWKB4 keypad and user/master code.
iButton key.
Arm/Disarm by Zone.
to arm the system without exit delay, use one of the following system arming methods:
Free of charge phone call.
SMS text message.
eWK1/eWK2/eWK2A wireless keyfob
eGR100 middle-ware.
Set exit delay
notE:
Alternatively, you can set exit delay value to "0" in order to arm the system without exit delay by any available method.
notE:
eKB3/eKB3W/eWKB4 keypad buzzer will only beep if the keypad is operating in the partition where exit delay countdown is in
progress.
ESIM384 Installation and Configuration Manual v1.1
SMS text message content:
ssss_eXItDeLAY:p,ext
SMS
Value: ssss – 4-digit SMS password; p – partition number, range – [1... 4], ext – exit delay
duration, range – [0... 600] seconds.
Example: 1111_EXITDELAY:1,20;3,43
Menu path:
OK → iiii → OK → PRIMARY SettINGS → OK → eXIt DeLAY → OK → PARtItION 1... 4 → OK →
EKB2
ext → OK
Value: iiii – 4-digit installer code;, ext – exit delay duration, range – [0... 600] seconds.
Enter parameter 72, partition number and exit delay duration:
EKB3/
72 pp ext #
EKB3W/
Value: pp – partition number, range – [01... 04], ext – exit delay duration, range – [0... 600]
EWKB4
seconds.
Example: 7203259#
ElDES
Config-
this operation may be carried out from the PC using the ELDES Configuration software.
uration
software
or
ssss_eXItDeLAY:p,ext;p,ext;p,ext;p,ext