Eldes ESIM364 User Manual

Eldes ESIM364 User Manual

Gsm alarm and management system
Hide thumbs Also See for ESIM364:

Advertisement

GSM ALARM AND MANAGEMENT SYSTEM
ESIM364
USER MANUAL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ESIM364 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Eldes ESIM364

  • Page 1 GSM ALARM AND MANAGEMENT SYSTEM ESIM364 USER MANUAL...
  • Page 2: Esim364

    User Manual v1.2 Valid for ESIM364 v02.04.01 and up Safety instructions Please read and follow these safety guidelines in order to maintain safety of operators and people around: ing in GSM 850/900/1800/1900 bands. standard. Phase Null AC 230V AC/DC 50 Hz/DC 24V...
  • Page 3: Table Of Contents

    Arm by EKB2 Keypad in STAY Mode Manually ....19 About User Manual ... 21 ............22 3.6 Viewing System Information .............. 23 usage of alarm system ESIM364. It is very impor- ........23 tant to read the user manual before starting to use ........24 the system.
  • Page 4: General Information

    1. General Information 1.1 Short Description of Main Definitions Definition Description System; alarm system Keypad EKB2 EKB3 User phone number; User 1... 10 System phone number User password Zone PGM output Partition...
  • Page 5 TAMPER ALARM Tamper violated READY System is ready to be armed. System is not ready to be armed – one or more NOT READY ARMED STAY + CONFIGURATION MODE Delay, Instant or BURGLARY ALARM system is armed. MANUAL ELDES ESIM364 V1.2...
  • Page 6 READY NOT READY main power supply is lost. low battery. battery dead or missing. battery failed. siren failed. date/time not set. GSM antenna failed. Audio Indication Visual Indication and stays in this state until the system is disarmed.
  • Page 7: Partitions

    [STAY] [INST] READY tor SYSTEM arming when present: main power supply is lost. low battery. battery dead or missing. battery failed. siren failed. date/time not set. GSM antenna failed. Audio Indication Visual Indication disarmed. 1.4 Partitions MANUAL ELDES ESIM364 V1.2...
  • Page 8: Technical Specifications

    2. Technical Specifications 2.1 Electrical & Mechanical Characteristics Electrical & Mechanical Characteristics Main Power Supply Up to 80mA 900mA Shielded Number of Zones on Board Up to 100 meters Unshielded Up to 100 meters Unshielded 150mA Unshielded Supported Temperature Sensor Model Up to 30 meters Unshielded Supported iButton®...
  • Page 9 AK U - LED Functionality Fig. No.3 STAT Connector Functionality TIP* RING* DATA BUZ- BUZ+ PGM output terminals Z1 - Z6 BELL- Siren negative terminal BELL+ Siren positive terminal AUX- AUX+ Main power supply terminals AKU- AKU+ MANUAL ELDES ESIM364 V1.2...
  • Page 10: Wiring Diagrams

    2.3 Wiring Diagrams 2.3.1 General Wiring AKU+ Backup Battery AKU- 12V 1.3-7Ah Metal cabinet PE terminal Fuse 500 mA ~16-24V ~230V 50Hz SIREN/BELL EPGM1 Fig. No. 2 1A max. iButton® key reader Relay module EKB3 EKB2 Temperature sensor Siren status monitoring BLACK - 3,3kΩ...
  • Page 11: Basic Configuration & Use

    EKB2 0... 9 0... 9 EKB3/ EKB3W NOTE: 3.1 Setting Up Date & Time NOTE ves this data from the monitoring station by itself. SMS text message content: Value: yyyy – year; mm Example: 1111_2011.12.15_13:45 MANUAL ELDES ESIM364 V1.2...
  • Page 12 3.2. Arming, Disarming the System & Turning Off the Alarm Don’t stand in movement sensor windows doors doors Fig. No. 7 3.2.1 Arm, Disarm & Turn off the Alarm by Phone Call ATTENTION User ESIM364 Fig. No. 8 3.5 Bypassing & Activating Zones.
  • Page 13 Bypassing & Activating Zones. 3.2.3 Disarm & Turn off the Alarm by SMS text message from any out of 10 preset user phone numbers: SMS text message content: Value: p Example: 1111_DISARM1,3,4 User ESIM364 Fig. No. 10 MANUAL ELDES ESIM364 V1.2...
  • Page 14: Arm By Ekb2 Keypad

    3.2.4 Arm by EKB2 Keypad EKB2 Enter user password (and select partition): Partitioned system: uuuu Non-partitioned system: uuuu [p] part-name Fig. No. 11 Value: uuuu – 4-digit user password; p part-name partition name. Example: 1111 [2] PART2 Non-partitioned system ARMING part-name menu.
  • Page 15 Partitioned system: uuuu Non-partitioned system: uuuu [p] part-name Fig. No. 12 Value: uuuu – 4-digit user password; p part-name partition name. Example: 1111 [2] PART2 Non-partitioned system Partitioned system part-name DISARMED NOTE: KEYPAD BLOCKED KEYPAD UNBLOCKED message. MANUAL ELDES ESIM364 V1.2...
  • Page 16 Switch keypad partition: Value: p Enter user password: uuuu Value: uuuu – 4-digit user password Example: 1111 ARMED User ESIM364 Fig. No. 14 3.4 Alarm Indications & Viewing Violated Zones / Tampers to 3.5 Bypassing & Activating Zones. ATTENTION: NOTE:...
  • Page 17 Switch keypad partition: Value: p Enter user password: uuuu Value: uuuu – 4-digit user password Example: 1111 ARMED will light and the system will reply same partition as the user password. User ESIM364 Fig. No. 16 ATTENTION: NOTE: MANUAL ELDES ESIM364 V1.2...
  • Page 18: Arm By IbuttonĀ® Key

    3.2.8 Arm by iButton® Key Fig. No. 17 User ESIM364 Fig. No. 18 3.5 Bypassing & Activating Zones. 3.2.9 Disarm & Turn off the Alarm by iButton® Key Fig. No. 19 User Fig. No. 20 ESIM364...
  • Page 19 3.2.10 Arm by EWK1 – Wireless Key-fob EWK1 Arm the system Fig. No. 21 User ESIM364 Fig. No. 22 3.5 Bypassing & Activating Zones MANUAL ELDES ESIM364 V1.2...
  • Page 20 3.2.11 Disarm & Turn off the Alarm by EWK1 – Wireless Key-fob EWK1 disarm the alarm system Disarm the system Fig. No. 23 User ESIM364 Fig. No. 24...
  • Page 21 3.2.12 Arm by EWK2 – Wireless Key-fob EWK2 Arm the system Fig. No. 25 User ESIM364 Fig. No. 27 3.5 Bypassing & Activating Zones MANUAL ELDES ESIM364 V1.2...
  • Page 22 3.2.13 Disarm & Turn off the Alarm by EWK2 – Wireless Key-fob EWK2 disarm the alarm system Disarm the system Fig. No. 28 User ESIM364 Fig. No. 29...
  • Page 23: Arm By Ekb2 Keypad In Stay Mode Manually

    User ESIM364 Fig. No. 30 3.4 Alarm Indications & Viewing Violated Zones / Tampers to 3.5 Bypassing & Activating Zones. NOTE: KEYPAD BLOCKED KEYPAD UNBLOCKED message. 3.2.5 Disarm & Turn off the Alarm by EKB2 Keypad. MANUAL ELDES ESIM364 V1.2...
  • Page 24 STAY uuuu Value: uuuu - 4-digit user password Example: STAY1111 Switch keypad partition: Value: p ARMED User ESIM364 Fig. No. 31 3.4 Alarm Indications & Viewing Violated Zones / Tampers to 3.5 Bypassing & Activating Zones. ATTENTION: NOTE: 3.2.7 Disarm & Turn off the...
  • Page 25 3.4 Alarm Indications & Viewing Violated Zones / Tampers able to listen on his/her mobile phone to what is happening in area surrounding ESIM364 unit. This feature is pro- User ESIM364 Fig. No. 32 NOTE: User ESIM364 Fig. No. 33 3.6 Viewing System Information.
  • Page 26 EKB2 using any method. Navigate through the following menu path using OK tamper number: Menu path: View violated tamper: TAMPER 1... 76 EKB3/ SYSTEM EKB3W SYSTEM. 3.10 Indication of System Faults. anymethod. 3.5 Bypassing & Activating Zones and arm the alarm system after-wards. EKB2 Menu path: BYPASS...
  • Page 27: Viewing System Information

    Fig. No. 34 See also 3.9 Managing Temperature Information. 3.7 Managing Periodical System Information 3.6 Viewing System Information is User ESIM364 Fig. No. 35 SMS text message content: Value: ff Example: 1111_INFO:2.15 (every 2nd day at 15:00) NOTE: MANUAL ELDES ESIM364 V1.2...
  • Page 28 10 preset user phone numbers: SMS text message content: Example: 1111_INFO:0.0 message. User ESIM364 Fig. No. 36 3.8 Viewing Zone & PGM Output Information SMS text message content: Example: 1111_STATUS information: PGM output names. User ESIM364 Fig.
  • Page 29: Managing Temperature Information

    10 preset user phone numbers: SMS text message content: Value: n Example: 1111_TEMP1:MIN:0,MAX:0 SMS text message content: Example: SMS text message content: Example: message. User ESIM364 Fig. No. 39 3.6 Viewing System Information MANUAL ELDES ESIM364 V1.2...
  • Page 30: Indication Of System Faults

    EKB2 Menu path: 1... 8 3.10 Indication of System Faults Message FLT EKB2 FAULTS Menu path: FAULTS Name Description Main power supply is lost BATTERY DEAD/MISS BATTERY FAILED 2 or higher SIREN FAILED Date/time not set GSM ANTENNA FAILED...
  • Page 31 A. System fault indication - enter command: B. Violated high zone indication – enter command: C. Violated tamper indication – enter command: Example: Result Zone LED section - A Zone LED section - B (flashing) (illuminated continously) MANUAL ELDES ESIM364 V1.2...
  • Page 32: Controlling Electrical Appliances

    SMS text message content: Value: oo out-name – PGM output name. Example: 1111_Pump:ON number from any out of 10 preset user phone numbers: SMS text message content: Value: oo out-name – PGM output name. Example: 1111_C2:OFF message. User ESIM364 Fig. No. 40...
  • Page 33 – PGM output name. Example: 1111_C3:OFF:13.25.56 message. User ESIM364 Fig. No. 41 NOTE: NOTE: 3.13 Viewing Event Log The event log is of LIFO (last in, first out) ones. EKB2 Menu path: uuuu Value: uuuu - 4-digit user password. MANUAL ELDES ESIM364 V1.2...
  • Page 34: If The Alarm System Is Connected To Monitoring Station

    4. If the Alarm System is Connected to Monitoring Station NOTE: at www.eldes.lt/en/download...
  • Page 35 MANUAL ELDES ESIM364 V1.2...
  • Page 36 Made in Lithuania. www.eldes.lt...

Table of Contents