Disable system
control from any
phone number
9. DatE anD tIME
the system comes equipped with internal real-time clock (RtC) that keeps track of the current date and time. Once the system is up and
running, the user must set the correct date and time, otherwise the system will not operate properly. By default, after shutting down and
starting up the system, the date and time must be set again.
Set date and time
attEntIon!
to set date and time using eKB3/eKB3W/eWKB4 command, described above, you MUSt enter the Configuration mode first!
ELDES Configuration software provides the ability to select the time Zone option. the user may also choose Get PC time option, which
instantly provides the exact PC time.
notE:
When the system is connected to the monitoring station via IP connection (see 30. MonItorInG StatIon) and/or when eLDeS
Cloud Services feature is in use (see 36. ElDES CloUD SErVICES), the date and time will be automatically synchronized with the monitoring
station or eLDeS Cloud Services server upon the system startup. However, SIA IP data format users must enable time synchronization feature
using ELDES Configuration software.
9.1. automatic Date and time Synchronization
this feature enables the system to set the date and time automatically without the user being involved in this process. the system sup-
ports the following methods of automatic date and time synchronization that are used automatically on system start-up and periodically
(by default – every 30 days):
36
36
EN
SMS text message content:
ssss_StR:OFF
SMS
Value: ssss – 4-digit SMS password.
Example: 1111_STR:OFF
Menu path:
OK → iiii → OK → PRIMARY SettINGS → OK → CALL/SMS SettINGS → OK → CtRL FROM ANY
EKB2
NUM → OK → DISABLe → OK
Value: iiii – 4-digit installer code;
Enter parameter 12 and parameter status value:
EKB3/
12 0 #
EKB3W/
EWKB4
Example: 120#
ElDES
Config-
this operation may be carried out from the PC using the ELDES Configuration software.
uration
software
SMS text message content:
ssss_yyyy.mt.dd_hr:mn
SMS
Value: ssss – 4-digit SMS password; yyyy – year; mt – month, range – [01... 12]; dd – day, range
– [01... 31]; hr – hours, range – [00... 23]; mn – minutes, range – [00... 59].
Example: 1111_2014.03.16_14:33
Menu path:
a)
OK → uumm → OK → DAte/tIMe SettINGS → OK → yyyy-mt-dd hr:mn → OK
EKB2
b)
OK → iiii → OK → PRIMARY SettINGS → OK → DAte/tIMe SettINGS → OK → yyyy-mt-dd
hr:mn → OK
Value: uumm – 4-digit user/master code; yyyy – year; mt – month, range – [01... 12]; dd – day,
range – [01... 31]; hr – hours, range – [00... 23]; mn – minutes, range – [00... 59]; iiii – 4-digit
installer code.
Enter parameter 66, date and time:
EKB3/
66 yyyy mt dd hr mn#
EKB3W/
Value: yyyy – year; mt – month, range – [01... 12]; dd – day, range – [01... 31]; hr – hours, range
EWKB4
– [00... 23]; mn – minutes, range – [00... 59].
Example: 66201405291235#
ElDES
Config-
this operation may be carried out from the PC using the ELDES Configuration software.
uration
software
ESIM384 Installation and Configuration Manual v1.1
Need help?
Do you have a question about the ESIM384 and is the answer not in the manual?
Questions and answers