S12; V, View Configuration - Fibocom G510 User Manual

G5/g6-family at commands
Hide thumbs Also See for G510:
Table of Contents

Advertisement

ATS0=3
OK
ATS0?
003
OK
4.1.5

S12

This command handles the selection of the guard time, which is stored in S-Register 12, and specifies the
behavior of escape characters during ODM connection.
Note: For a guard time specified by S-Register 12, no character should be entered before or after "+++".
The duration between escape codes must be smaller than the guard time.
Command
Set
Read
The following table shows the S12 parameters.
<Parameter>
<guard_time>
4.1.6 &V, View Configuration
This command reports the current S-registers.
Command
Execute
G5/G6-Family AT Commands User Manual
Syntax
Response/Action
S12=<guard_tim
OK
e>
+CME ERROR:
<err>
S12?
<guard_time>
OK
Description
ODM escape character guard time (units of 50 msec). Range is 0 to 255.
The default value is 50.
Syntax
Response/Action
&V
ACTIVE PROFILE:
...
(profile data)
STORED PROFILE 0:
Remarks
The Set command sets the ODM
escape character guard time value if
all parameters are valid.
The Read command displays the
current ODM escape character guard
time.
Remarks
The Execute command displays the
current active configuration.
Page 26 of 243