Clck, Facility Lock - Fibocom G510 User Manual

G5/g6-family at commands
Hide thumbs Also See for G510:
Table of Contents

Advertisement

AT+CLCK="ai",2
+CLCK: 1,1
+CLCK: 1,2
+CLCK: 1,4
OK
AT+CPWD="ai","old password","new password"
OK

8.1.6 +CLCK, Facility Lock

This command locks, unlocks or interrogates a Module or a network facility <fac> (any kind of call barring
program). A password is mandatory for performing locking and unlocking actions, but not for querying.
The features of the Module that are affected by this are the keypad power-up operation and fixed dialing
list. When querying the status of a single call barring program <mode>=2, the <status> for each call type
will be returned.
For <fac>="SC", SIM Card PIN setting and for <fac>="FD", SIM Fixed Dialing memory setting, the
<class> is irrelevant (For more information about <class>, refer to the following table shows the +CLCK
parameters.). The <passwd> for "SC" is SIM PIN, and for "FD" it is SIM PIN2.
Command
Syntax
Set
+CLCK=<fa
c>,<mode>[,
<passwd>[,
<classx>]]
Read
+CLCK?
Test
+CLCK=?
G5/G6-Family AT Commands User Manual
Response/Action
For <fac> where <class> is
irrelevant(SC, FD):
+CLCK=<fac>,2
+CLCK: <status>
For <fac> with several supported
<class>es:
+CLCK=<fac>,2
+CLCK: <status>,<class1>
[<CR><LF>
+CLCK: <status>,<class2>
[...]]
OK
ERROR
+CLCK: (list of supported <fac>s)
Remarks
The Set command performs the
specified <mode> action on the
specified <fac>.
The Test command returns the list
of supported facilities.
Page 126 of 243