10.1.5+IPR, Local Terminal Serial Port Rate

This command is responsible for setting and saving the request baud rate. This numeric extended-format
parameter specifies the data rate at which the Module accepts commands. Specifying a value of 0
disables the function and allows operation only at rates automatically detectable by the Module. The
specified rate takes effect following the issuing of any result code(s) associated with the current command
line.
The <rate> value specified is the rate in bits per second at which the terminal-Module interface operates,
for example, 19200 or 115200. The rates supported by the Module are manufacturer-specific. However,
the +IPR parameter permits setting any rate supported by the Module during online operation.
The UART is configured to rates of 1200, 4800, 9600, 19200, 38400, 57600, 115200, 230400 bits per
second according to the parameters of the +IPR command.
Using AT+IPR=<rate> with a <rate> value other than 0 disables the auto baud rate detection feature. The
entered baud rate is stored in the Module and is restored after power up.
9600, 14400, 19200, 57600, 115200 and 230400.
Note: +IPR is similar to +CBAUD, but with the ability to save.
The baud rate after ATZ (or AT&F) is the last baud rate that was set by +IPR, or +CBAUD.
Command
Set
G5/G6-Family AT Commands User Manual
1
2400
2
4800
3
9600
4
14400
5
19200
6
28800
7
33600
8
38400
10
57600
11
115200
12
230400
13
460800