Cbc, Battery Charger Connection - Fibocom G510 User Manual

G5/g6-family at commands
Hide thumbs Also See for G510:
Table of Contents

Advertisement

AT+MTSM=3,30,-10,40
reports for every 30 seconds.
OK
+MTSM: -20
+MTSM: -12
+MTSM: 47
AT+MTSM?
+MTSM: 3,30,-10,40
OK
AT+MTSM=0
OK
AT+MTSM?
+MTSM: 0
OK

10.1.3+CBC, Battery Charger Connection

This command enables a user to query the battery power level.
Command
Read
The following table shows the +CBC parameters.
<Parameter>
<bcs>
<bcl>
G5/G6-Family AT Commands User Manual
// Set to out-off boundary (-10 to +40 Celsius) unsolicited
// Unsolicited current report out-off the Low boundary.
// Unsolicited report out-off the Low boundary after 30 seconds.
// Unsolicited report out-off the High boundary after Nx30 seconds
// Read the current setting.
// Set to stop the unsolicited report.
// Read the current setting.
Syntax
Response/Action
+CBC
+CBC: <bcs>,<bcl>
OK
Description
Battery status values
0
Battery powered
1
Externally powered - not implemented in Module
Note: The Module input power source is connected via the battery pins only,
so it is always battery powered.
VBAT voltage value, A decimal value represents the returned digital value.
The input level multiplied by 1000.