The following table shows the +MIPRTCP parameters.
<Parameter>
Socket_ID
Left
Data
Example:
+MIPRTCP: 3,0,7171

13.1.11+MIPDSETS, Set Size and Timeout for Output Received Data

This command causes the Module to set a max length and time span when send out data to user.
Command
Set
Read
Test
The following table shows the +MIPDSETS parameters.
<Parameter>
length
AT Commands User Manual
Description
1,2,3,4 - Number of valid sockets.
Size of received Data still left in protocol stack.
Data string received with 0-F hexadecimal digits. String ends with a
<CR>.
Syntax
Response/Action
+MIPDSETS=<So
OK
cket_ID>,<length>
or:
[,<TimeSpan>]
ERROR
+MIPDSETS: <err>
+MIPDSETS?
+MIPDSETS:
[<Socket_ID>,<Current length
Settings>,< TimeSpan>]
OK
For all ACTIVE sockets.
+MIPDSETS=?
+MIPDSETS: (1-4),(list of
supported <length>s),),(list of
supported <TimeSpan>s)
OK
Description
Max length when send out data:
Remarks
TimeSpan is
defined in
milliseconds.
Page 213 of 243