Example:
Opening socket 2 already.
AT+MIPSEND=2
>>This is the data in HEX<timeout>
OK
+MIPPUSH: 2,0
+MIPSEND: 2,0,2048
OK

13.2.3+MIPSEND (Data length)

Command
Syntax
Set
+MIPSEND
=<Socket_I
D>,<Data_l
en>
Example:
Opening socket 2 already.
AT+MIPSEND=2,10
AT Commands User Manual
+MIPSEND:
<Socket_ID>,<Status>,<FreeSiz
e>
or:
ERROR
Response/Action
+MIPPUSH:
<Socket_ID>,<Status>
+MIPSEND:
<Socket_ID>,<Status>,<F
reeSize>
or:
ERROR
Send any data without encode.
The data buffer range is
0<buffer<=1400 bytes.
After timeout, the data will be
push automatic and returns to
regular AT command mode.
The default timeout is 12s.
Remarks
After command received, Module will
respond "><CR><LF>".
Send any data in HEX. The data buffer
range is 0<data_len<=1400 bytes.
When Module receive the corresponding
length data, the data will be push automatic
and returns to regular AT command mode.
Notes: The redundant data will be lost.