Read
The following table shows the S94 parameters.
<Parameter>
<n>
11.2.5 S96, Echo Canceling
This command suppresses a large amount of the output sound picked up by the input device (cancels all
echo).
Command
Set
Read
The following table shows the S96 parameters.
<Parameter>
<n>
11.2.6 +CALM, Alert Sound Mode
This command handles the selection of the Module's Call and SMS alert sound mode. The value of the
command is saved after a power cycle.
Command
Syntax
Set
+CALM=<call_mode
>,<SMS_mode>
G5/G6-Family AT Commands User Manual
ATS94?
+S94:<n>
OK
Description
0-7 Sidetone range.
0 is lowest sidetone (not mute).
The default value is 004.
Syntax
Response/Action
ATS96=<n>
OK
or:
+CME ERROR: <err>
ATS96?
+S96:<n>
OK
Description
0-7 echo canceling range.
0 is lowest echo canceling (not mute).
The default value is 004.
Response/Action
OK
or:
The Read command returns the
sidetone status.
Remarks
The Set command sets the echo
canceling status.
The Read command returns the echo
canceling status.
Remarks
The Set command sets the Call and
SMS alert sound mode.
Page 177 of 243