Transfer With E-Mail; Details Of Data - Epson RC90 Manual

Robot controller
Hide thumbs Also See for RC90:
Table of Contents

Advertisement

6.3.3 Transfer with E-mail

Follow this procedure to transfer the data by e-mail that was saved to the USB memory.
(1) Insert the USB memory to a PC that supports sending of e-mail.
(2) Make sure that the USB memory has following folders.
(3) Send all the folders by e-mail.
NOTE
Delete files that do not relate to the project before transfer.
This function is used to send the data to the system director and EPSON from the end
users for problem analysis.

6.4 Details of Data

The following data files are created by the Controller status storage function.
File Name
Backup.txt
CurrentMnp01.PRM
CurrentStatus.txt
ErrorHistory.csv
InitFileSrc.txt
MCSys01.MCD
SrcmcStat.txt
ProjectName.obj
GlobalPreserves.dat *1
WorkQueues.dat
MCSRAM.bin
MCSYSTEMIO.bin
MCTABLE.bin
MDATA.bin
SERVOSRAM.bin
VXDWORK.bin
All files related to
project except
ProjectName.obj *2
*1 When the Controller firmware version is Ver.1.0.*.*, GlobalPreserves.dat is not stored.
*2 Storage of "All files related to project except ProjectName.obj" can be specified by a setting.
RC90 (EPSON RC+ 7.0) Rev.8
B_RC90_serial number_data status was saved
→ Exmaple:B_RC90_12345_
Information file
for restore
Robot
parameter
Save status
Error history
Initial setting
Robot setting
Hardware
information
OBJ file
Global Preserve
variables
WorkQue
information
Inner
information
of
Robot
operation
Project
Setup & Operation 6. Memory Port
2013-10-29_092951
Outline
File with information for Controller restore.
Saves information such as ToolSet.
Saves program and I/O status.
Saves various settings of the Controller.
Saves information of connected robot.
Saves installation information of hardware.
Result of project build.
Prg file is not included.
Saves values of Global Preserve variables.
Saves information of Queues information of the WorkQue.
When [Include project files when status exported] check box
is checked in EPSON RC+ 7.0 menu-[Setup]-
[System Configuration]-[Controller]-
[Preference], the project file is stored.
Includes program files.
37

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rc90-b