Maintenance 9. Troubleshooting
No.
Emergency stop circuit failure was detected.
9001
Disconnection or other failure was found in
one of the redundant inputs.
Safeguard circuit failure was detected.
9002
Disconnection or other failure was found in
one of the redundant inputs.
Initialization failure.
9003
Failed to initialize the firmware.
Initialization failure.
9004
Failed to initialize the DU.
Check the DU power and the connection.
Initialization failure.
9005
Failed to initialize the DU.
Check the connection.
Initialization failure.
9006
Failed to initialize the Remote I/O.
Check the Remote I/O setting.
Battery voltage of the CPU board backup is
9011
lower than the specified voltage. Replace the
CPU board battery.
5V input voltage for CPU board is lower
9012
than the specified voltage.
24 V input voltage for the motor brake,
9013
encoder and fan is lower than the specified
voltage.
Internal temperature of the Controller is
9014
higher than the specified temperature.
Rotating speed of the controller fan is below
9015
the allowed speed. (FAN1)
Rotating speed of the controller fan is below
9016
the allowed speed. (FAN2)
Internal temperature of the Controller is
9017
higher than the specified temperature.
DU1 3.3V input voltage for the board is
9021
lower than the minimum allowed voltage.
DU1 5V input voltage for the board is lower
9022
than the minimum allowed voltage.
DU1 24 V input voltage for the motor brake,
9023
encoder and fan is lower than the specified
voltage.
200
Message
Remedy
Check whether no disconnection, earth fault, or
short-circuit of the emergency stop input signal
exits. Then reboot the controller.
Check whether no disconnection, earth fault, or
short-circuit of the safeguard input signal exits.
Then reboot the controller.
This is likely because of the controller
hardware failure. Check the wiring is correct.
If the error is not cleared after the controller is
rebooted, contact us.
The number of set Drive Unit(s) disagrees with
the number of recognized Drive Unit(s).
Check the wirings of power supply and
between Control Unit and Drive Unit are
correct. If the error is not cleared after the
controller is rebooted, contact us.
This is likely because of the Drive Unit
hardware failure. Check the wiring is correct.
If the error is not cleared after the controller is
rebooted, contact us.
Check the Remote I/O setting value
Replace the battery for the CPU board
immediately. Keep the controller ON as long
as possible until the battery is replaced.
If normal voltage is not generated by 5V power
supply alone, replace the power supply.
If normal voltage is not generated by 24V
power supply alone, replace the power supply.
Stop the controller as soon as possible and
check whether the ambient temperature of the
controller is not high.
Check whether the filter is not clogged up.
Check whether the filter of the controller is not
clogged up. Replace the fan.
Check whether the filter of the controller is not
clogged up. Replace the fan.
Stop the controller as soon as possible and
check whether the ambient temperature of the
controller is not high.
Check whether the filter is not clogged up.
If normal voltage is not generated by 3.3V of
Drive Unit 1 power supply alone, replace the
power supply.
If normal voltage is not generated by 5V of
Drive Unit 1 power supply alone, replace the
power supply.
If normal voltage is not generated by 24V of
Drive Unit 1 power supply alone, replace the
power supply.
Note 1
Current
value
Current
value
Current
value