No.
Message
3293
Disk type was not specified.
3295
Conveyor area ID was not specified.
Database file number was not
3296
specified.
Vision calibration name was not
3297
specified.
Vision object type ID was not
3298
specified.
3299
Shutdown mode ID was not specified.
Version of linked OBJ file does not
3301
match.
Linked OBJ file does not match the
3302
compiled I/O label.
Linked OBJ file does not match the
3303
compiled user error label.
Linked OBJ file does not match the
3304
compiled compile option.
Linked OBJ file does not match the
3305
compiled link option.
Linked OBJ file does not match the
3306
compiled SPEL option.
3307
Duplicate function.
3308
Duplicate global preserve variable.
3309
Duplicate global variable.
RC90 (EPSON RC+ 7.0) Rev.8
Remedy
Type of the disk that is subject to file
manipulation is not specified in ChDisk
statement. Refer to SPEL+ Language
Reference "ChDisk Statement" and
specify a proper disk type.
Area ID that is subject to count the
queue data is not specified in
Cnv_QueLen function. Refer to
SPEL+ Language Reference
"Cnv_QueLen Function" and specify a
proper area ID.
Data base number that is subject to
operation is not specified in OpenDB,
CloseDB, DeleteDB, UpdateDB, and
SelectDB function. Refer to SPEL+
Language Reference "OpenDB
Statement" and specify a proper database
number.
Calibration name is not specified in
VCal statement. Specify a name of
calibration that is subject to calibrate.
Vision object type is not specified in
VCreateObject statement. Refer to
Vision Guide 7.0 Properties & Results
Reference "VCreateObject Statement"
and specify a proper object type.
Shutdown mode value is not specified in
ShutDown statement and ShutDown
function. Refer to SPEL+ Language
Reference "Shutdown Statement" and
specify a proper mode value.
Not all project files are compiled in the
same version.
Rebuild the project.
The project configuration has been
changed. Rebuild the project.
The project configuration has been
changed. Rebuild the project.
The project configuration has been
changed. Rebuild the project.
The project configuration has been
changed. Rebuild the project.
The project configuration has been
changed. Rebuild the project.
The same function name is used for more
than one file. Correct the program
(function name).
The same global preserve variable name
is used for more than one file.
Correct the program (variable name).
The same global variable name is used
for more than one file.
Correct the program (variable name).
Maintenance 9. Troubleshooting
Note 1
Note 2
159