Epson RC90 Manual page 152

Robot controller
Hide thumbs Also See for RC90:
Table of Contents

Advertisement

Maintenance 9. Troubleshooting
No.
Message
Array failure. Failed to calculate the
2250
size of the variable area.
Cannot allocate enough memory for
2251
Redim statement.
Cannot allocate enough memory for
2252
ByRef.
Cannot compare characters with
2253
values.
Specified data is beyond the array
2254
bounds. Cannot refer or update
beyond the array bounds.
Variable overflow or underflow.
2255
Specified variable is out of value
range.
Specified array subscript is beyond the
2256
maximum allowed range.
Task number is out of the available
2260
range.
2261
Specified task number does not exist.
Robot number is out of the available
2262
range.
Output number is out of the available
2263
range. The Port No. or the Device
No. is out of the available range.
Command argument is out of the
available range. Check the
2264
arguments. Added data 1: Passed
value. Added data 2: argument order.
Joint number is out of the available
2265
range.
2266
Wait time is out of available range.
Timer number is out of available
2267
range.
2268
Trap number is out of available range.
2269
Language ID is out of available range.
Specified D parameter value for the
2270
parallel process is out of available
range.
2271
Arch number is out of available range.
2272
Device No. is out of available range.
136
Remedy
Rebuild the project.
Reduce the number of subscripts to be
specified for Redim. Perform Redim
modestly.
Reduce the number of array's subscripts
to be seen by ByRef.
Check whether the string type and the
numeric data type are not compared.
Review the program.
Check the number of array's subscripts
and data. Review the program.
The value that exceeds the range of
Double type is specified. Review the
program.
Reduce the number of subscripts to be
specified. For available subscripts, see
the online help.
For available task number, see the online
help. Review the program.
Review the program.
The available Robot number is 1.
Review the program.
For available output number, see the
online help. Review the program.
For available range of argument, see the
online help. Review the program.
Available Joint number is from 1 to 6.
Review the program.
Available wait time is from 0 to
2147483. Review the program.
Available timer number is from 0 to 15.
Review the program.
Available trap number is from 1 to 4.
Review the program.
For available language ID, see the online
help. Review the program.
Available D parameter value is from 0 to
100. Review the program.
Available arch number is from 0 to 7.
Review the program.
The specified number representing a
control device or display device is out of
available range. For available device
number, see the online help. Review
the program.
Note 1
The number
The number of
of data to be
array
referred or
subscripts
updated
The specified
task number
The specified
task number
The specified
robot number
The specified
output number
The Added
What number
value
argument?
The specified
joint number
The specified
wait time
The specified
timer number
The specified
trap number
The specified
language ID
The specified
D parameter
value
The specified
arch number
The specified
device number
RC90 (EPSON RC+ 7.0) Rev.8
Note 2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rc90-b

Table of Contents