No.
7902
Fieldbus line defect.
7903
Fieldbus device not configured.
7904
Fieldbus invalid board.
7905
Fieldbus connection denied.
7906
Fieldbus invalid device configuration.
7907
Fieldbus general error.
7908
Fieldbus configuration error.
7909
Fieldbus slaves were not detected.
Force sensing.
7950
Force sensing is invalid.
Force sensing.
7951
Force sensor axis is invalid.
Force sensing.
7952
Sensor read error
Force sensing.
7953
Sensor initialization error.
Force sensing.
7954
Sensor is not initialized.
Force sensing.
7955
Sensor value exceeds maximum value.
RC90 (EPSON RC+ 7.0) Rev.8
Message
Remedy
Check the connection of the
communication cable for the fieldbus.
Check whether the communication
cable for the fieldbus is powered. (if
the fieldbus requires power supply)
Check the connection of the fieldbus
slave.
Check that the fieldbus master board is
installed.
Reboot the computer where the fieldbus
master board is installed.
Replace the fieldbus master board.
Check that the fieldbus master board is
installed.
Reboot the computer where the fieldbus
master board is installed.
Replace the fieldbus master board.
-
Check that the fieldbus master board is
installed.
Reboot the computer where the fieldbus
master board is installed.
Replace the fieldbus master board.
Check that the fieldbus master board is
installed.
Reboot the computer where the fieldbus
master board is installed.
Replace the fieldbus master board.
Check the fieldbus master setting.
Register the slave to the fieldbus master
by accompanying applicomIO Console
application.
-
-
-
-
-
-
Maintenance 9. Troubleshooting
Note 1
Note 2
199