Maintenance 9. Troubleshooting
No.
6001
Calibration number is out of range.
6002
Calibration is not defined.
6003
Camera orientation is out of range.
6004
TwoRefPoints flag is out of range.
Cannot calculate the point position because there
6005
is invalid data.
Calibration failed. Cannot calculate because
6006
there is invalid data.
Coordinate transformation failed. Cannot
6007
calculate because there is invalid data.
6009
Calibration file name is invalid.
6010
Calibration file is not found.
6012
Failed to read the calibration file.
6013
Failed to write the calibration file.
6014
9 pixel coordinate points should be specified.
6015
18 pixel coordinate points should be specified.
6016
9 robot coordinate points should be specified.
6017
18 robot coordinate points should be specified.
9 robot coordinate points and 1 reference point
6018
should be specified.
9 robot coordinate points and 2 reference points
6019
should be specified.
6502
Vision process Communication error (-3)
6503
Vision process Memory error (-11)
6506
Vision process Error at modeling (-14)
6507
Vision process Recovery error(-15)
6508
Vision process Invalid repetition count (-16)
6509
Vision process Invalid mode (-17)
6510
Vision process Invalid threshold value (-18)
6511
Vision process Invalid polarity (-19)
6512
Vision process File open failed (-20)
6513
Vision process Initialization error (-21)
6514
Vision process Status error (-22)
6517
Vision process Invalid image format (-25)
6520
Vision process Invalid property value (-100)
Vision process Exposure termination process
6521
failed (-201)
Vision process Invalid Blob property
6533
ThresholdLow value (-11004)
Vision process Invalid Blob property
6534
ThresholdHigh value (-11005)
Vision process Invalid Blob property Polarity
6535
value(-11006)
Vision process Invalid Blob property
6536
NumberToFind value (-11007)
Vision process Invalid Blob property MinArea
6537
value (-11008)
184
Message
Remedy
Correct the calibration number.
Perform calibration.
Correct the CameraOrientation
value.
Correct the TwoRefPoint value.
Re-teach the points.
Perform point teaching and
calibration again.
Reteach the points.
Correct the calibration file name.
Correct the calibration file name.
Correct the calibration file name.
Check access permission for the
project folder.
Make sure that at least 9 results are
obtained in the vision sequence.
Make sure that at least 18 results are
obtained in the vision sequence.
Reteach the points.
Reteach the points.
Perform point teaching and
calibration again.
Perform point teaching and
calibration again.
Check the connection with the
camera (cable, setting).
Reboot the RC+.
Change the target and teach again.
Specify the file of appropriate
format.
Set a value in the valid range.
Set a valid value.
Set a value in the valid range.
Set a value in the valid range.
Specify a correct file.
Reinstall the RC+.
Check the connection with the
camera.
Specify the image file of readable
format.
Set a value in the valid range.
Disable Windows Firewall.
Set a value in the valid range.
Set a value in the valid range.
Set a value in the valid range.
Set a value in the valid range.
Set a value in the valid range.
RC90 (EPSON RC+ 7.0) Rev.8
Note 1
Note 2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rc90-b

Table of Contents