Maintenance 9. Troubleshooting
No.
Message
3254
I/O bit width was not specified.
3255
ByRef was not specified.
3256
Variable type was not specified.
Condition expression does not
3257
evaluate to Boolean value.
RS232C port number was not
3258
specified.
Network communication port number
3259
was not specified.
3260
Language ID was not specified.
3261
Expected '.'.
Vision Sequence Name was not
3262
specified.
Vision Sequence Name or Calibration
3263
Name was not specified.
Vision Property Name or Result Name
3264
was not specified.
Vision Property Name, Result Name
3265
or Object Name was not specified.
Vision Calibration Property Name was
3266
not specified.
3267
Task type was not specified.
156
Remedy
I/O bit size (I/O port width) is not
specified in IODef, IOLabe function.
Refer to SPEL+ Language Reference
"IODef Function" and specify a proper
I/O bit size.
Although the ByRef is specified in the
function declaration, no ByRef is
specified for calling. Specify the
ByRef parameter.
Variable type is not specified in Global
statement. Specify a proper variable
type.
Condition expression in If, ElseIf, Do,
and Loop statement must return a
Boolean value. Correct the condition
expression to return a Boolean value.
RS-232C port number is not specified in
ChkCom function. Refer to SPEL+
Language Reference "ChkCom
Function" and specify a proper port
number.
Network communication port number is
not specified in ChkNet function. Refer
to SPEL+ Language Reference "ChkNet
Function" and specify a proper port
number.
Language ID is not specified in
ErrMsg$ function. Refer to SPEL+
Language Reference
"ErrMsg$ Function" and specify a
proper language ID.
Add '.'.
Vision sequence name is not specified in
Vision Guide commands such as VSet,
VGet, and VRun. Add a sequence
name.
Vision sequence name or calibration
name is not specified in VSet and VGet
statements. Add a sequence name or
calibration name.
Vision property name or result name is
not specified in VSet and VGet
statements. Add a property name or
result name.
Either of Vision property name, result
name, or object name is not specified in
VSet and VGet statements. Add either
of a property name, result name, or
object name.
Vision calibration property name is not
specified in VSet and VGet statements.
Add a property name.
Task type is not specified in Xqt
statement. Refer to SPEL+ Language
Reference "Xqt Statement" and specify a
proper task type.
Note 1
RC90 (EPSON RC+ 7.0) Rev.8
Note 2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rc90-b

Table of Contents