Epson RC90 Manual page 156

Robot controller
Hide thumbs Also See for RC90:
Table of Contents

Advertisement

Maintenance 9. Troubleshooting
No.
Message
I/O input/output byte number is out of
2345
available range or the board is not
installed.
I/O input/output word number is out of
2346
available range or the board is not
installed.
Memory I/O bit number is out of
2347
available range.
Memory I/O byte number is out of
2348
available range.
Memory I/O word number is out of
2349
available range.
Command allowed only when virtual
2350
I/O mode is active.
Specified command cannot be
2353
executed from the Command window.
Cannot execute the I/O output
2354
command when the Enable Switch is
OFF.
File failure.
2360
Failed to open the configuration file.
File failure.
2361
Failed to close the configuration file.
File failure.
2362
Failed to open the key of the
configuration file.
File failure.
2363
Failed to obtain a string from the
configuration file.
File failure.
2364
Failed to write in the configuration file.
File failure.
2365
Failed to update the configuration file.
The string combination exceeds the
2370
maximum string length.
2371
String length is out of range.
Invalid character is specified after the
2372
ampersand in the Val function.
Illegal string specified for the Val
2373
function.
String Failure. Invalid character code
2374
in the string.
Cannot use ' 0 ' for Step value in
2380
For...Next.
Relation between For...Next and
2381
GoSub is invalid. Going in or out of
a For...Next using a Goto statement.
Cannot execute Return while executing
2382
OnErr.
Return was used without GoSub.
2383
Review the program.
140
Remedy
Review the program.
Check whether the expansion I/O board
and Fieldbus I/O board are correctly
detected.
Review the program.
Check whether the expansion I/O board
and Fieldbus I/O board are correctly
detected.
Review the program.
Review the program.
Review the program.
The command can be executed only for
virtual I/O mode.
Execute specified command from the
program.
Execute the I/O output command with
the enable switch gripped.
Restore the controller configuration.
Restore the controller configuration.
Restore the controller configuration.
Restore the controller configuration.
Restore the controller configuration.
Restore the controller configuration.
The maximum string length is 255.
Review the program.
The maximum string length is 255.
Review the program.
Review the program.
Review the program.
Review the program.
Check the Step value.
Review the program.
Review the program.
Review the program.
Note 1
Byte number
Word number
Bit number
Byte number
Word number
Combined
string length
The specified
length
RC90 (EPSON RC+ 7.0) Rev.8
Note 2